NOTE: in all modes, inputs must be connected to devices
having normally open contacts.
Connect cables of device controlling the first input between
terminals
L3 (START)
and
L6 (COM)
of the control unit.
Connect cables of device controlling the second input between
terminals
L4 (START P.)
and
L6 (COM)
of the control unit.
ST
AR
T
ST
AR
T P
.
COM
L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11
The START function can also be activated by pressing UP key
outside the programming menu or by means of a remote control
stored on channel 1 (see relevant instructions of MR receiver).
The START P. function can also be activated by pressing DOWN
key outside the programming menu or by means of a remote
control stored on channel 2.
5.4 - ACTIVATION INPUTS
CITY1-EVO is equipped with two activation inputs (START
and START P.), whose operation depends on the programmed
operation modes (see
Strt
parameter of programming menu)
Standard mode (DEFAULT)
START = START (it controls the total opening of the gate)
START P. = START PEDONALE (it controls the partial opening of the
gate)
Open/Close command
START = APERTURA (it controls the opening of the gate)
START P. = CHIUSURA (it controls the closing of the gate)
Dead man operation
START = APERTURA (it controls the opening of the gate)
START P. = CHIUSURA (it controls the closing of the gate)
The gate is opened or closed until the contact of the START or
START P. entrance remains closed; the gate stops immediately
when the contact is opened.
Timer mode
This function allows programming the gate opening time during
the day, by making use of an external timer.
START = START (it controls the total opening of the gate)
START P. = START PEDONALE (it controls the partial opening of the
gate)
The gate remains open for the time in which the contact on the
START or START P. entrance remains closed; as soon as the contact
is open the pause time count down will start, after which the gate
will be closed again.
m
ATTENTION: Automatic closing must be enabled
(parameter
Ch.AU
).
NOTE: If the parameter
t.APP
=
0
the timer connected to
START P. does not cause the opening, but can inhibit the