ENGLISH
- 52 -
PARAMETER
VALUE
DESCRIPTION
AntE SCor
MEMO
Pot1
Motor M1 power
60
60
30 - 100
The displayed value is the percentage of max. motor power.
WARNING:
In case an hydraulic motor is used, set value 100
Pot2
Motor M2 power
60
60
30 - 100
The displayed value is the percentage of max. motor power.
WARNING:
In case an hydraulic motor is used, set value 100
SPUn
Start off
When the gate is standstill and it begins moving, the initial inertia
must be faced, therefore, if your gate is quite heavy, its doors could
not move.
In case the
SPUn
(pickup) function is activated, for the first 2 seconds
of motion of each door, the control unit will ignore both
Pot1
and
Pot2
values and it will give motors the maximum power command
in order to overcome the gate inertia.
Si
Si
Si
Function activated
no
Function deactivated
rAM
Starting ramp
4
4
0 - 6
In order not to stress too much the motor, when the motion starts the
power is gradually increased, until reached the set value or 100% if
the take-off is enabled.
Higher is the set value, longer the length of time of the ramp, that is
the time necessary to reach the value of nominal power.
rA.AP
Slow down in opening
25
15
no
Function deactivated
1 - 50
This menu allows regulating the percentage of the ride/drive that is
carried out at reduced speed during the last opening stretch
rA.Ch
Slow down in closing
25
15
no
Function deactivated
1 - 50
This menu allows regulating the percentage of the ride/drive that is
carried out at reduced speed during the last closing stretch
t.CvE
Fast closing time after slowing down
0.0” 0.0”
0.0” - 5.0”
If a slowing time other than 0 is set up, it could be likely that the gate
speed is not enough for the lock to fasten during the closing phase.
In case this function is enabled, once the slowing down phase is
finished, the control unit will give a normal speed command (that is to
say, with no slowing down) for the set up time, and then it will open
the gate for a second fraction, to avoid leaving the motor under stress.
m
PLEASE NOTE:
Set to
0
if the gate is not fitted with electro-
locks or if slowing is disabled.
tE.M
Enabling the test motor
The unit performs an operation test on the motor before starting the
automation.
ATTENTION:
disable this function only if it is necessary to perform
emergency manoeuvres.
Si
Si
Si
Function activated
no
Function deactivated
Содержание CITY1-EVO