61574415.fm
Omron E5GC Temperature Controller
Appendix B: Temperature Controller
B- 3
Setting Protection Levels (Figure 1.1)
1. Press and hold the level and mode keys for at least three seconds. The control-
ler will enter
Protect Level
.
2. The first parameter,
Operation/Adjustment Protection
, will read as
oAPt
on the
PV display. It should be set to
0
. If not, make adjustments with the Up or Down
Arrow Keys.
3. Press the Mode Key. This moves to the
Initial Setting/Communications Protec-
tion
parameter, which will read as
iCPt
. It should be set to
1
.
4. Press the Mode Key again. This moves to the
Setting Changes Protection
parameter, which will read as
utPt
. It should be set to
off
.
Initial Settings (Figure 1.2)
1. Press the Level Key for at least three seconds. The PV display will flash after one
second and temperature control will stop. The controller is then in
Initial Settings
Level
.
2. The
Input Type
parameter will display as
In-T
. It should be set to
7
. This setting
corresponds to the J type thermocouple used in V-TEK sealers.
3. Select the
Temperature Unit
parameter, displayed as
d-u
, by pressing the Mode
Key. It should set to
C
, which selects Celsius.
4. Select the
Control Period
parameter, displayed as
CP
, by pressing the Mode Key.
It should be set to
5
.
5. Select the
Direct/Reverse Operation
parameter, displayed as
orEu
. It should be
set to
or-r
.
6. Select the
PID/On-Off
parameter, displayed as
CntL
. It should be set to
Pid
.
7. Select the
Self-tuning
parameter, displayed as
St
. It should be set to
off
.
8. Select the
Alarm Type
parameter, displayed as
ALt1
. It should be set to
1
.
9. Select the
Set Point High Limiter
, displayed as
sl-H
. It should be set to
850
.
10.Select the
Set Point Low Limiter
, displayed as
sl-L
. It should be set to
-100
.
Figure 1.1
Figure 1.2
Содержание OEM TM-50 SMD
Страница 2: ......
Страница 4: ......
Страница 10: ...Safety Warning Labels 61685113 fm vi ...
Страница 28: ...16 OEM TM 50 User s Guide Machine Overview 61685225 fm ...
Страница 29: ...Chapter 2 Controller Contents The OEM TM 50 Controller 16 Extended Software Option 22 Using the Vision Port 25 ...
Страница 43: ...6174007 fm Using the Vision Port Chapter 2 Controller 29 Vision Hookup Example Figure 2 33 ...
Страница 74: ...60 OEM TM 50 User s Guide Electrical Connections 6174322 fm Figure 4 6 ...
Страница 95: ...61004015 fm Appendix A Sensors A 1 Appendix A Sensors ...
Страница 102: ...Service and Parts Contacts 61053915 fm Page 2 ...
Страница 104: ......
Страница 106: ...TM 50 OEM Sensors Spare Parts List D219368 2 fm Page 1 of 1 ...
Страница 108: ......
Страница 110: ......
Страница 111: ......
Страница 112: ...751 Summit Avenue Mankato MN 56001 507 387 2039 FAX 507 387 2257 www vtekusa com Email info vtekusa com ...