![V-TEK OEM TM-50 SMD Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/v-tek/oem-tm-50-smd/oem-tm-50-smd_user-manual_3083383059.webp)
61685321.fm
Operation
Chapter 3: Setup and Operation
45
Check Carrier Tape Alignment
To ensure an accurate count, select a spot on the loading
track as a reference point for the first and last parts
counted. Examples of reference points include the edge
of the stainless steel
Carrier Tape Guide
, one of the fas-
tener heads, or the
Track Width Lock Knob
.
Set the Counter
Set the counter
STOP
value in the
Controller
menu to the
batch size to be run, if necessary, and then reset the counter
to zero.
Place Components
1.
The integrated place system will place the component in the pocket and advance the tape
accordingly.
2.
Observe the carrier tape as it advances to confirm it is moving smoothly into the sealer and
the cover tape is being positioned correctly. Adjust tape advance speed, seal and cover tape as
needed.
3.
When the end of the taped carrier reaches the
Take-up Reel
, attach it to the reel and set the
Take-up Tension Control
so that the carrier winds onto the
Take-up Reel
but does not apply
excessive pressure to the carrier tape.
4.
Once all components have been taped or the batch size
has been reached, reset the counter to zero and run out the
amount of empty carrier tape needed to make the reel’s
leader.
Cut the carrier tape and replaced the finished reel with a new
take-up reel. Repeat the above process.
Examples of Ref. Points
Figure 3.19
1>RESET count to 0
2>SET Stop value
REV 2.xx
Figure 3.20
1>RESET count to 0
2>SET Stop value
REV 2.xx
Figure 3.21
Содержание OEM TM-50 SMD
Страница 2: ......
Страница 4: ......
Страница 10: ...Safety Warning Labels 61685113 fm vi ...
Страница 28: ...16 OEM TM 50 User s Guide Machine Overview 61685225 fm ...
Страница 29: ...Chapter 2 Controller Contents The OEM TM 50 Controller 16 Extended Software Option 22 Using the Vision Port 25 ...
Страница 43: ...6174007 fm Using the Vision Port Chapter 2 Controller 29 Vision Hookup Example Figure 2 33 ...
Страница 74: ...60 OEM TM 50 User s Guide Electrical Connections 6174322 fm Figure 4 6 ...
Страница 95: ...61004015 fm Appendix A Sensors A 1 Appendix A Sensors ...
Страница 102: ...Service and Parts Contacts 61053915 fm Page 2 ...
Страница 104: ......
Страница 106: ...TM 50 OEM Sensors Spare Parts List D219368 2 fm Page 1 of 1 ...
Страница 108: ......
Страница 110: ......
Страница 111: ......
Страница 112: ...751 Summit Avenue Mankato MN 56001 507 387 2039 FAX 507 387 2257 www vtekusa com Email info vtekusa com ...