18
OEM TM-50 User’s Guide
The OEM TM-50 Controller
6174007.fm
Advance
This screen (Figure 2.10) prompts the user to
enter the number of pockets to advance each
time the foot switch is pressed or an advance
command is sent to the controller using the I/O
port.
The user can choose any value up to the max-
imum allowed. The maximum is the number of
pockets that fit into the length of the loading
track. Enter the number of pockets to be
advanced and then press ENT. If an invalid
value is chosen, the software will ask for
another value. Choose a smaller number and
press ENT again.
Speed
This screen (Figure 2.11) prompts the user to
enter the speed the machine will advance the
tape.
Any speed level between 5 and 250 may be
entered. A recommended speed for normal
operation is generally between 125 and 150.
Entering the desired setting with the keypad
and pressing ENT will set the speed choice
and return the user to the Setup Menu. If ESC
is pressed from this screen before pressing
ENT, the speed setting will not be changed.
Dwell
This screen (Figure 2.12) allows the operator
to adjust the length of time the heat shoes will
remain in contact with the tape during a seal
stroke.
Any value between 50 milliseconds and 999
milliseconds may be entered. The longer the
shoes remain down on the tape, the stronger
the resulting seal will be. A recommended
dwell time for normal operation is generally
around 300 milliseconds. Enter the dwell time
in the space provided and press ENT.
This setting is not applicable when using PSA
cover tape.
Jog
This screen (Figure 2.13) is used to adjust the
position of the carrier tape in between
advances.
This is useful, for example, to line up the car-
rier pockets with an inspection camera or with
a reference point for counting the first and last
pocket of a run. The default jog distance is
approximately 40 microns (.0016 inches).
Pressing the 0 (zero) key will toggle the jog
distance from 40 microns to 2 mm increments
and back again.
Enter the number of
parts to advance
then press ENT
Now 10
Figure 2.10
ENTER SPEED 5 - 250
THEN PRESS ENT
NOW 100
Figure 2.11
Enter Dwell Time
from 50 to 999 mS
then press ENT
NOW 400
Figure 2.12
KEY 0 CHANGES ADV
FWD JOG REV
40 mi
Figure 2.13
Содержание OEM TM-50 SMD
Страница 2: ......
Страница 4: ......
Страница 10: ...Safety Warning Labels 61685113 fm vi ...
Страница 28: ...16 OEM TM 50 User s Guide Machine Overview 61685225 fm ...
Страница 29: ...Chapter 2 Controller Contents The OEM TM 50 Controller 16 Extended Software Option 22 Using the Vision Port 25 ...
Страница 43: ...6174007 fm Using the Vision Port Chapter 2 Controller 29 Vision Hookup Example Figure 2 33 ...
Страница 74: ...60 OEM TM 50 User s Guide Electrical Connections 6174322 fm Figure 4 6 ...
Страница 95: ...61004015 fm Appendix A Sensors A 1 Appendix A Sensors ...
Страница 102: ...Service and Parts Contacts 61053915 fm Page 2 ...
Страница 104: ......
Страница 106: ...TM 50 OEM Sensors Spare Parts List D219368 2 fm Page 1 of 1 ...
Страница 108: ......
Страница 110: ......
Страница 111: ......
Страница 112: ...751 Summit Avenue Mankato MN 56001 507 387 2039 FAX 507 387 2257 www vtekusa com Email info vtekusa com ...