61
English
M2 USER MANUAL
WARNING
A leaking battery cap may lead to the
destruction of the M2 by water seeping in or
cause the M2 to switch off without prior notice.
Always open the battery compartment in a dry
and clean environment.
1. Dry the M2 with a soft towel.
2. Unscrew the battery cap with a tool
or, in an emergency, with a size-
appropriate coin.
3. Replace the main O-ring (replacement
O-rings are available from your authorized
SCUBAPRO dealer).
4. Remove the isolation sticker.
5. Open the battery latch with tweezers.
6. Remove the empty battery and recycle
it in environmentally friendly way.
7. Insert the new battery with “+” side on
top.
8. Close the battery latch.
9. Attach the isolation sticker.
10. Screw the battery cap back in place.
11. Check the M2 functions and housing
sealing.
WARNING
We recommend having the M2 battery replaced by
an authorized SCUBAPRO dealer. The change must
be made with particular care in order to prevent
water from seeping in. The warranty does not cover
damages due to improper placement of the battery
or the incorrect closing of the battery cap.
The M2 stores the tissue saturation
information in a non-volatile memory,
so the battery can be replaced at any
time between dives without the loss of
information.
F
NOTE: After a dive, while on the
surface, the M2 stores tissue
desaturation data once every hour
until desaturation is complete. If a
battery is changed while the M2 has
remaining desaturation time, the
tissue data will not be lost, but the M2
will reference the last stored data set.
As a consequence, the data displayed
on the surface screen after the battery
change (desaturation time, surface
interval, NO-FLY time and CNS O
2
)
may be different from the values
displayed just prior to battery removal.
After replacing the battery, you must set the
date and time and calibrate the compass.
The O-ring must be replaced each time the
M2 is opened.
The battery case must be completely
closed (see marking).
The following parts of the transmitter are
shown in the drawing above:
1. Transmitter cap screws.
2. HP port O-ring.
3. Main O-ring.
4. CR 2/3 AA battery.
5. Transmitter cap.
To change the battery in the high-pressure
transmitter:
1. Dry the transmitter with a soft towel.
2. Open the screws.
Содержание M2