Hallett Instruction Manual
Released on 8-Aug-19
– GH2B
Page 9
UV Pure Technologies Inc. © 2019
Potable Water
Hallett Models
Hallett
1000P
Hallett
750PN
Hallett
750P
Hallett
500PN
Hallett
500P
Max. Flow Rate
1
100 gpm
378 L/min
22.7 m
3
/hr
27.4 gpm
104 L/min
6.2 m
3
/hr
30 gpm
114 L/min
6.8 m
3
/hr
16.5 gpm
62 L/min
3.8 m
3
/hr
20 gpm
75.7 L/min
4.5 m
3
/hr
Performance
Certifications
2
USEPA
UVDGM
2006
NSF/ANSI
55 Class A
3
rd
Party
NSF/ANSI
55 Class A
3
rd
Party
Min. UVT
3
95%
80%
50-75%
75%
50-75%
Flow Restrictor
No
Yes
Optional
Yes
Optional
Pressure Drop
4.4 psig
(30 kPa)
22.7 psig
4
(156 kPa)
7.4 psig
(51 kPa)
22.7 psig
4
(156 kPa)
3.2 psig
(22 kPa)
Lamp Type
Amalgam
LPHO
LPHO
LPHO
LPHO
Lamp Life
5
16
months
12
months
12
months
12
months
12
months
Cycles/day
6
6-12
2
2
2
2
UV Sensor
Quad
Dual
Dual
Dual
Dual
Built-in Purge
Valve
Standard
Standard
Standard
Standard
Standard
Automatic
Quartz Sleeve
Cleaning Device
Standard
Standard
Standard
Standard
Standard
Wiper Position
Switch
Standard
Standard
Standard
Standard
Standard
Lamp Heaters
No
Standard
Standard
Standard
Standard
4-20mA Output
Optional
Optional
Optional
Optional
Optional
Modbus
connectivity
Optional
Optional
Optional
Optional
Optional
Power Draw
403W
222W
222W
196W
196W
Inlet & Outlet
Port size
2" MNPT
1" MNPT
1" MNPT
1" MNPT
1" MNPT
Nominal
Dimensions
(L x W x D)
56x11x9"
(142x29x
22cm)
40x10x9"
(103x24x
22cm)
40x10x9"
(103x24x
22cm)
36x10x9"
(93x24x
22cm)
36x10x9"
(93x24x
22cm)
1
Based on UV Dose of 40mJ/cm
2
at alarm setpoint.
2
NSF/ANSI 55 Class A certifications substantiated by NSF International only. Third party
validations are pending.
3
The Hallett 1000P can operate over a wide range of UVTs with the UV dose EPA
validated between 16-200mJ/cm
2
. Consult UV Pure to correctly configure the unit. The
Hallett 750P and 500P can be configured to high or low UVT applications by service
technicians.
4
The flow restrictor adds significant pressure drop so the value presented is at 75% of
maximum flow capacity.
5
Amalgam lamp lifetime is 12,000hrs/500 days and LPHO lifetime is 9000hrs/375 days
6
Exceeding the recommended daily cycles will accelerate the age of the UV lamps.
LPHO lamps perform more reliably when operated 24/7.
Содержание Crossfire Technology Hallett 1000NC
Страница 41: ...Hallett Instruction Manual Released on 8 Aug 19 GH2B Page 41 UV Pure Technologies Inc 2019 Figure 7 9A...
Страница 50: ...Hallett Instruction Manual Released on 8 Aug 19 GH2B Page 50 UV Pure Technologies Inc 2019...
Страница 51: ...Hallett Instruction Manual Released on 8 Aug 19 GH2B Page 51 UV Pure Technologies Inc 2019...
Страница 52: ...UV Pure Technologies Inc 455 Milner Ave Unit 1 Toronto Ontario M1B 2K4 www uvpure com...