Hallett Instruction Manual
Released on 8-Aug-19
– GH2B
Page 35
UV Pure Technologies Inc. © 2019
is clean, no disassembly is required and the unit can be closed. Restart the
unit by plugging it in.
Step 4:
If the quartz sleeve is dirty on the outside, proceed to wipe it down
with a clean lint-free cloth and rubbing alcohol to remove the dirt. If the quartz
sleeve is dirty on the inside, proceed with in-place cleaning or disassembly.
In-place cleaning
This procedure will clean the quartz sleeve without its removal from the unit.
This is a quick and easy procedure that works well in most cases.
Tools Needed
slotted screwdriver
Philips screwdriver
Pipe wrench
Step 1:
Fill a bucket or container with 1 gallon (4 liters) of clean water - this
will be required later to clean the quartz sleeve. A squeeze bottle is useful for
applying water or cleaning solution
to the inside of the quartz sleeve.
Step 2:
Shutdown and unplug the unit.
Step 3:
Shut off the water supply and relieve the pressure.
Step 4:
Open the UV Chamber as described in
Accessing UV Chamber
section.
Step 5:
Place another bucket under the unit and drain the unit until there is
about 1” (3cm) of water left in the quartz sleeve (see
Draining the Unit
section).
Step 6
: Disconnect the fitting at the top outlet port of the UV unit. If the
stainless flexible hose was installed, disconnect the hose opposite from the
UV unit then bend the open end upwards
– this will make the next step
easier.
Step 7
: Add about 2 oz. (60cc) of cleaning solution to the top hose/manifold.
The cleaning solution can be a citric acid, vinegar or other non-hazardous
solutions.
Any solution used should be thoroughly rinsed out afterwards.
Fill the rest of the quartz sleeve with water.
Step 8
: Let the cleaning solution remain in the quartz sleeve for at least 10-
20 minutes.
Step 9:
Manually
turning the wiper may greatly assist the cleaning process.
To do this, remove the top plastic cover then remove the motor and turn the
wiper shaft with a slotted screwdriver (counterclockwise while looking at the
shaft). If the optional wiper positioner switch is installed, leave the trigger cam
in place.
UV
UV
UV
Содержание Crossfire Technology Hallett 1000NC
Страница 41: ...Hallett Instruction Manual Released on 8 Aug 19 GH2B Page 41 UV Pure Technologies Inc 2019 Figure 7 9A...
Страница 50: ...Hallett Instruction Manual Released on 8 Aug 19 GH2B Page 50 UV Pure Technologies Inc 2019...
Страница 51: ...Hallett Instruction Manual Released on 8 Aug 19 GH2B Page 51 UV Pure Technologies Inc 2019...
Страница 52: ...UV Pure Technologies Inc 455 Milner Ave Unit 1 Toronto Ontario M1B 2K4 www uvpure com...