Hallett Instruction Manual
Released on 8-Aug-19
– GH2B
Page 25
UV Pure Technologies Inc. © 2019
open only if treatment levels are adequate, otherwise it will remain closed.
This is the normal operating mode of the unit.
During normal operation if a power outage occurs, upon return of the power,
the unit will start up automatically and perform a diagnostic check. After a 10-
15 minute stabilization period, the unit will begin treating if treatment levels
are adequate, otherwise an alarm will be issued if the unit is not treating.
Test the wiper motor and purge valve - see Advanced Settings menu, items
2.7.1.2 and 2.7.1.3.
Flushing Instructions
Flushing the system is required after installation or after any disassembly and
cleaning. Flushing may also be required to remove colored or contaminated
water from the unit. Most filters (if installed) also require flushing prior to use
– follow the manufacturer’s recommendations.
The system may be flushed in two ways. It can be done manually by
disassembling the unit and filling and draining the unit by hand (see
In-place
Cleaning
section). Flushing may also be done while the unit is operating. Plug
in the unit and open a tap closest to the unit and have the water flow for a
minimum of 15 minutes.
Shutting Down of Unit and Seasonal Use
To shut the unit down, initiate the Power Down procedure located as the
second item in the Settings Menu. When this procedure is complete, simply
unplug the unit.
The Hallett can operate for extended periods of time without water usage
as
long as pressurized water is present to allow for purging.
The unit may
be shutdown in the case of seasonal residences or during a vacation. If the
possibility of freezing exists, the unit and any valves and filters must be
drained. (See
Draining the Unit
section.)
Disinfecting the Plumbing
Disinfection of the household or facility plumbing should be performed after
the Hallett has been installed and is operating. This procedure should also be
done if the unit is not functioning normally; if a bypass has been used; or if
there has been a high background bacteria count in a water sample. UV Pure
has found that disinfecting the plumbing will ensure that any potential bacteria
or contaminants in the distribution system are treated prior to system use.
Please note that this procedure is ineffective against protozoa that can be
found in surface water or shallow wells under the influence of surface water.
Under these circumstances, it is important to perform the disinfecting
procedure and then operate the Hallett. UV Pure has found that this
procedure does not work with sediments or heavy biofilm and encrustations,
which must be removed mechanically.
UV Pure recommends sanitizing the household or facility plumbing by adding
Содержание Crossfire Technology Hallett 1000NC
Страница 41: ...Hallett Instruction Manual Released on 8 Aug 19 GH2B Page 41 UV Pure Technologies Inc 2019 Figure 7 9A...
Страница 50: ...Hallett Instruction Manual Released on 8 Aug 19 GH2B Page 50 UV Pure Technologies Inc 2019...
Страница 51: ...Hallett Instruction Manual Released on 8 Aug 19 GH2B Page 51 UV Pure Technologies Inc 2019...
Страница 52: ...UV Pure Technologies Inc 455 Milner Ave Unit 1 Toronto Ontario M1B 2K4 www uvpure com...