AUTOMATIC OPERATION
1 Press the Auto button, the unit enter in automatic mode. In this mode, the Master fan unit It detects the environmental parameters (temperature, umidity
and brightness) and making procedures and elaborations, mentioned below, to ensure the best environmental comfort. Every single slave adjusts the fan
depending of its light and humidity sensors.
EXTRA CYCLE OPERATION AND RECOVERY REGENERATIVE MODULAT
The master, in AUTO mode, It has the purpose of controlling the time of input and extraction for optimize the regenerative recovery cycle of the system. To the
first activation of the "Auto" mode, after 10 minuts and later every 12 hours, the fan unit "Master" performs the procedure "Extra-cycle" to detect the difference
in temperature between the internal and external environments, in order to determine the duration of the "Auto Cycle" most suitable, which it will also be
adopted by eventual "Slave" ventilation units in the system. The procedure "Extra-cycle" lasts 5 minutes, during which the communication with the remote
control is inhibited; in this phase, every eventual command given with the remote control will have as feedback three flashes of the LEDs. The duration of the
recovery cycle is automatically determined by the outcome of "Extra-loop" process and can vary between 30 and 200 seconds, which shall be distributed
equally between the extraction phase and that of input.
DEHUMIDIFICATION
A humidity sensor allows to every ventilation unit of detect the environmental humidity, and in case of necessity, autonomously activate high-speed air
extraction cycles to reduce humidity and improve the environmental comfort. Depending on ambient humidity conditions, the procedure can have a
duration between 2 and 12 minutes (during which time the communication with the remote control is inhibited) and can recur every hour. The drying cycle is
suspended in "night mode."
Note: this functionality is disabled by default; to enable it, see paragraph “paragraph settings”.
BRIGHTNESS SENSOR
A light sensor allows, for each individual ventilation units, autonomously to adopt the minimum speed (extra-low) during the night. If it is necessary the sensors
di luminosità the light sensors can be excluded, in this case the night speed can only be activated manually by means of the remote control button.
Note: this functionality is disabled by default; to enable it, see paragraph “paragraph settings”.