3NV-2
1-3-43
U425
Setting: [DP]
1. Measure the distance from the leading edge to the black belt (inside) of the original at A.
2. Enter the measured value using the +/- keys in [Lead].
3. Measure the distance from the left edge to the black belt (inside) of the original at B.
4. Enter the measured value using the +/- keys in [Main Scan].
5. Measure the distance from the black belt of leading edge (inside) to the black belt of trailing
edge (inside) of the original at C.
6. Enter the measured value using the +/- keys in [Sub Scan].
7. Press the start key. The value is set.
Figure 1-3-13
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Item No.
Description
A
C
B
Original for adjustment (P/N: 302AC68243)