3NV
1-4-5
1-4-3 Electrical problems
Troubleshooting to each failure must be made in the order of the numbered symptoms.
Problem
Causes
Check procedures / corrective measures
(1)
The LED lamp
does not turn on
when an original is
present on the DP.
1. Defective connector
cable or poor con-
tact in the connector.
Reinsert the connector. Also check for continuity within the
connector cable. If none, replace the cable.
DP original sensor and DP main PWB (YC4_A)
DP LED PWB and DP main PWB (YC4_B)
2. Defective sensor.
Replace the DP original sensor.
3. Defective PWB.
Replace the DP LED PWB or DP main PWB and check for
correct operation.
(2)
The size of the
original on the DP
is not displayed
correctly.
1. Defective connector
cable or poor con-
tact in the connector.
Reinsert the connector. Also check for continuity within the
connector cable. If none, replace the cable.
DP original width switch and DP main PWB (YC2)
DP original length switch and DP main PWB (YC2)
2. Defective switch.
Replace the DP original width switch or DP original length
switch.
3. Defective PWB.
Replace the DP main PWB and check for correct operation.
(3)
DP feed motor
does not operate.
1. Defective connector
cable or poor con-
tact in the connector.
Reinsert the connector. Also check for continuity within the
connector cable. If none, replace the cable.
DP feed motor and DP main PWB (YC5)
2. Defective drive trans-
mission system.
Check if the rollers and gears rotate smoothly. If not,
grease the bushes and gears. Check for broken gears and
replace if any.
3. Defective motor.
Replace the DP feed motor.
4. Defective PWB.
Replace the DP main PWB and check for correct operation.
(4)
DP conveying
motor does not
operate.
1. Defective connector
cable or poor con-
tact in the connector.
Reinsert the connector. Also check for continuity within the
connector cable. If none, replace the cable.
DP conveying motor and DP main PWB (YC14)
2. Defective drive trans-
mission system.
Check if the rollers and gears rotate smoothly. If not,
grease the bushes and gears. Check for broken gears and
replace if any.
3. Defective motor.
Replace the DP conveying motor.
4. Defective PWB.
Replace the DP main PWB and check for correct operation.
Содержание DP 770
Страница 1: ...Service Manual Document Processor D3 Rev 0 Date 0 201 3NVSM06 ...
Страница 2: ...Service Manual Document Processor D3 Rev 0 Date 0 201 3NVSM06 ...
Страница 5: ...This page is intentionally left blank ...
Страница 11: ...This page is intentionally left blank ...
Страница 17: ...3NV 1 1 4 This page is intentionally left blank ...
Страница 21: ...3NV 1 2 4 This page is intentionally left blank ...
Страница 67: ...3NV 1 3 46 This page is intentionally left blank ...
Страница 85: ...3NV 1 5 10 This page is intentionally left blank ...
Страница 87: ...3NV 1 6 2 This page is intentionally left blank ...
Страница 95: ...3NV 2 1 8 This page is intentionally left blank ...