USA57 Revision
1.2
27
Command:
g
Begin Loop Block
Type:
Program Control Command
Syntax: g
Range:
N/A
Description:
This command signifies the beginning of a loop
Example:
/1
g
P1000M1000D1000M500G10R<CR>
“/”
Is the start character. Lets Accuriss know that a command string will follow.
“1”
Is the device address, (this is preset at the factory).
“g”
Informs Accuriss a loop is beginning
“P1000” Move 1000 steps in positive direction
“M1000” Wait
1000
milliseconds
“D1000” Move 1000 steps in negative direction
“M1000” Wait
1000
milliseconds
“G10”
Repeat all commands between the “G10” command and the “g” command loop
10 times
“R”
Instructs Accuriss to run the command(s) that are in the communication buffer.
“<CR>” Tells Accuriss that the command string is complete and causes the command to
be executed since an R is included in the command string.