Appendix G
Oscillating (sinusoidal) Scan
The Sinusoidal scan feature requires firmware V6.7+.
The Accuriss can be commanded to automatically scan in an oscillating (sinusoidal) manner.
The amplitude of the oscillating motion is set by the “
aA
” command.
Example: Entering a
/1aA51200R
command
sets the number of microsteps the motor will move
in each direction during an oscillating (sinusoidal) move. Any changes in this value will become
valid as the motion passes through the zero position.
The frequency of the oscillating motion is set by the “
aW
” command.
Example: Entering a
/1aW1000R
command
sets frequency to be:
f = (X)*20000 / (1024*65536), where
X
is 1000 in this example.
To exit from this mode, set the amplitude to zero with a
/1aA0R
command
.