USA57 Revision
1.2
23
Command:
F
Set Positive Direction
Type:
System Control Command
Syntax: F
n
Range:
n = 0: Motor rotation away from home is the positive direction
1: Motor rotation toward home is the positive direction
Initial Value:
0
Description:
Change direction of rotation considered positive. (Note: this command should
only be used once after the power is on.)
Example:
/1
F
1R<CR>
“/”
Is the start character. Lets Accuriss know that a command string will follow.
“1”
Is the device address, (this is preset at the factory).
“F1”
Sets the direction to rotate toward home to positive
“R”
Instructs Accuriss to run the command(s) that are in the communication buffer.
“<CR>” Tells Accuriss that the command string is complete and causes the command to
be executed since an R is included in the command string.
Содержание Accuriss 57 Series
Страница 1: ... USA57 Revision 1 2 Accuriss 57 Series Integrated Motor Drive Control System USA57 USER S MANUAL ...
Страница 4: ...USA57 Revision 1 2 4 Appendix I 101 Appendix J 103 ...
Страница 11: ...USA57 Revision 1 2 11 ...
Страница 102: ...USA57 Revision 1 2 102 Encoders must have 0 2V Low to 4V High swing at the input of the connector ...