USA57 Revision
1.2
25
Command:
L Acceleration
Rate
Type:
Motion Variable Command
Syntax: L
n
Range:
n = 0 to 5000 microsteps/sec
2
Initial Value:
1000
microsteps/sec
2
Description:
Sets the acceleration to a value
Note:
The acceleration rate does not scale with the encoder ratio “aE”
Example:
/1
L
1000R<CR>
“/”
Is the start character. Lets Accuriss know that a command string will follow.
“1”
Is the device address, (this is preset at the factory).
“L1000” Sets acceleration to 1000 microsteps/sec
2
“R”
Instructs Accuriss to run the command(s) that are in the communication buffer.
“<CR>” Tells Accuriss that the command string is complete and causes the command to
be executed since an R is included in the command string.
Содержание Accuriss 57 Series
Страница 1: ... USA57 Revision 1 2 Accuriss 57 Series Integrated Motor Drive Control System USA57 USER S MANUAL ...
Страница 4: ...USA57 Revision 1 2 4 Appendix I 101 Appendix J 103 ...
Страница 11: ...USA57 Revision 1 2 11 ...
Страница 102: ...USA57 Revision 1 2 102 Encoders must have 0 2V Low to 4V High swing at the input of the connector ...