Example
In a system with two keypads, one expansion, two readers, and a radio expansion, there will be the following
combination:
TS01
TS02
ER01
LT01
LT02
EW01
AS01
Suggestion:
Take note of the address of each individual device on the labels provided with the control panel.
6.3
USING THE SERVICE KEYPAD
For the system acquisition and programming operations, it is possible to use a keypad connected directly to the
SERVICE connector of the control panel via the specific cable (1067/016).
For more details, see paragraph 5.12.7
Connecting the cable for KP SERVICE keypad.
The service keypad must be acquired according to the method described above. The system automatically assigns it the
address n. 08.
At the end of the operation, it is possible to disconnect this keypad without generating tamper and therefore without
having to delete it. When inserted again, it does not require another acquisition and the keypad will be immediately
operative.
IMPORTANT!
Using the service keypad precludes the possibility of having 8 keypads on the system (as address
8 is already occupied, it will be possible to connect a maximum of 7 keypads).