DS1067-063D
87
LBT20064
Outputs programmed N.L.
Stand-by
On
RELAY OUTPUT
ELECTRICAL OUTPUT
POSITIVE reference
ELECTRICAL OUTPUT
NEGATIVE reference
Table 10 - Line diagram of output programmed N.L.
Suggestion:
To reduce the consumption of electricity, it is advisable to program all the relay outputs not being
used as N.L. or NOT USED.
5.12.7
Connecting the cable for KP SERVICE keypad
It is possible to connect a keypad directly to the control panel (SERVICE connector) without using the bus outputs. The
purpose is to be able to program the control panel more easily, without having to use one of the keypads already
installed elsewhere. To connect a keypad directly from the control panel to the SERVICE connector, connect the special
cable (1067/016) as illustrated in the figure:
Figure 61 - Cable for1067/016 KP SERVICE keypad
Keypad terminal
D
D
Wire colour
Black
White
Blue
Brown
The service keypad can be used only for this purpose.
IMPORTANT!
By using the Service keypad, the max number of keypads which can be used in the system is
decreased by one unit: it becomes 3 in the 1067/024 control panel, 7 in the 1067/032A and 1067/052A control
panels.
5.12.8
Connecting the telephone dialler
The connection of the 1067/024, 1067/032A or 1067/052A control panels to the telephone line by 1067/002A PSTN
communicator, is obligatory in order to conform to standard EN50131. Grade 3 and Grade 2.
In order to conform to standard EN50131 Grade 3, it is necessary to use an external dialler, like the ATS4, which is
certified EN50131 Grade 3.
In order to conform to standard EN50131 Grade 2, it is necessary to use a dialler like the ATS2. The 1067/002A PSTN
communicator is an ATS2.
Содержание 1067/024
Страница 118: ...DS1067 063D 118 LBT20064...