DS1067-063D
113
LBT20064
8.3
1067/052A CONTROL PANEL
Nominal power voltage ........................................................................................................ 230 Vac +10% -15% 50/60 Hz
Max absorption power at 230 V with power supply (MW RS-50-15) ......................................................................... 800 mA
Power output nominal voltage (MW RS-50-15) - Type A power supply .................................................................. 14.4 Vdc
Max current deliverable power supply (MW RS-50-15) ................................................................................................ 3.4 A
Ripple max with power supply (MW RS-50-15) ............................................................................ 150 mV p.p. with I = 3.4 A
Control panel operating voltage .............................................................................................................. 10.5 Vdc to 16 Vdc
Overload protection tripping current ........................................................................................................................... 16 Vdc
Max current absorbed by control panel board with 1067/002A at 12 Vdc
(with relays energised, default condition) .................................................................. 85 mA stand-by with balanced inputs
(with relays de-energised) ........................................................................................................ 65 mA with balanced inputs
Installable battery .............................................................................................................................................. 12 V
– 18 Ah
Nominal voltage of battery charger (
Note 1
) ........................................................................................................... 13.8 Vdc
Max current supplied to charge battery ..................................................................................................................... 850 mA
Max time for recharging battery to 80%................................................................................................................... 24 hours
Battery flat threshold ................................................................................................................................................... 11.5 V
Battery release threshold ............................................................................................................................................ 10.5 V
Automatic test battery................................................................................................................ every 24 hours (with mains)
Max current for external devices (keypads, sensors, sirens) taken from +, +V1, +V2 terminals:
Degree 3
– with ATS4 dialler and 60 hours autonomy .................................................................................................. 175 mA
(total 260 mA, of which 85 mA for the control panel with 1067/002A)
Degree 3
– with ATS4 dialler and 30-hour autonomy (
Note 2
)....................................................................................... 435 mA
(total 520 mA, of which 85 mA for the control panel with 1067/002A)
Degree 2
– with ATS2 dialler and 12 hours autonomy ................................................................................................ 1065 mA
(total 1150 mA, of which 85 mA for the control panel with 1067/002A)
Nominal voltage on the +SR terminal (
Note 3
) ........................................................................................................ 14.4 Vdc
Max current deliverable from the +SR terminal ................................................................ 200 mA (with overload protection)
Nominal voltage on the + terminal ................................................................................................................ 13.8 Vdc ±1,5%
Max current deliverable from + terminal ............................................................................. 1100 mA (with overload protection)
Nominal voltage on the +V1 terminal ........................................................................................................... 13.8 Vdc ±1,5%
Max current deliverable from +V1 terminal ....................................................................... 750 mA (with overload protection)
Nominal voltage on the +V2 terminal ........................................................................................................... 13.8 Vdc ±1,5%
Max total current deliverable from the +V2 terminals ....................................................... 750 mA (with overload protection)
Ripple max on oSR + +V1 +V2 with flat battery............................................................................ 150 mV (1,1%)
Max current and voltage of relay contact switch of outputs U1 and U2 ................................ 1 A
– 24 Vdc with resistive load
Max current deliverable from electric output U3 ........................................................................................................ 100 mA
Max current deliverable from electric outputs U4, U5, U6 ........................................................................................... 10 mA
Tamperproof switch ........................................................................................................................................... 1 A
– 24 Vdc
Max total length of control panel-peripheral serial Bus line ......................................................................................... 400 m
Max length of the audio line (audio bus) ............................................................................... 300 m with twin telephone line
Max length of the connection between each sensor or actuator and the control panel ............................................... 500 m
Max length of the connection between a fast sensor (roller, shock, ...) and the control panel .................................... 100 m
Max number possible code combinations ..................................................................................... from 10.000 to 1.000.000
Number of possible combinations of electronic keys .......................................................................... more than 1099 billion
Number of possible combinations of proximity keys ................................................................................. more than 4 billion
Programmable time entry ............................................................................................................................. 5 s to 5 minutes
Programmable exit entry .............................................................................................................................. 5 s to 5 minutes
Programmable alarm time ...........................................................................................30 s ÷ 15 minutes (default 3 minutes)
Programmable tamper alarm time ...............................................................................30 s ÷ 15 minutes (default 3 minutes)
Failure signal ................................................................................... optical (LED) and electric for control panel battery low,
fuses, low power supply expansion boards
Type of memory for programming, Events log, and diagnose log maintenance. .................................................. Data Flash
Certified functioning time (EN50131
– Environmental class II, general internal) ........................................... -10°C to +40°C
Average relative humidity during operation .................................................................................................................... 75%
Storage temperature ..................................................................................................................................... -20°C to +60°C
Degree of protection of casing ............................................................................................................................. IP40 / IK06
Dimensions (W x H x D) .......................................................................................................................... 435 x 320 x 93 mm
Weight (without battery) ............................................................................................................................................. 5600 g
For further information, see also paragraph 1.2.3
Note 1
): If the battery is not connected to the terminals of the connection cables, (red and black Faston) there is no power;
Note 2
): remotely assisted system with guaranteed intervention in case of lack of power;
Note 3
): in case of blackout, the
+SR
does not supply voltage.
Содержание 1067/024
Страница 118: ...DS1067 063D 118 LBT20064...