THE 1067/024, 1067/032A AND 1067/052A SYSTEMS
This chapter illustrates the 1067/024, 1067/032A and 1067/052A. More specifically, the following are analysed:
the main characteristics of the systems;
the system architecture and the maximum dimension possible;
the connectivity of systems towards to outside;
the various devices and accessories that make up the systems.
1.1
MAIN CHARACTERISTICS
The 1067/024, 1067/032A and 1067/052A wired intrusion alarm systems are modular, suitable for small - mid-sized
systems in residential, industrial, and service settings.
The components and main functions of the system are certified Grade 3, according to EN50131 standards.
Keypads, readers and expansions are connected to the control panel microprocessor by a proprietary field bus.
Detectors, sirens, and other signals are instead connected to the inputs and outputs present in the control panels and in
other devices connected to the bus.
All the inputs can be configured for both type and specialisation.
The remote alarm notifications can be made with vocal message, text message, or numerical protocol (for the connection
to alarm reception units).
The system can be managed locally and remotely by means of a land line, cell phone, text message, and Internet.
Other functions available are:
Programming via PC
equipped with FastPro software (2.30 or higher).
Saving of the program on a USB pen drive
to transfer the program between PCs and control panel or save a
back-up copy.
Firmware device updates
via USB interface with a pen drive.
Technological signalling
, that are activated by an event other than intrusion. Following an event of this type, the
system can command even specific actuations.
Advanced vocal alarm calls
, that allow specific alarm messages to be sent for individual zones and/or inputs.
Vocal message diffusion
, system armed, system disarmed, system diagnostic information can be communicated
to user via hands-free vocal messages diffused by vocal keypad.
Service vocal message
, the user may use any vocal keypad to issue a memo that will be reproduced locally until
the subsequent deactivation, by any vocal keypad
Remote ambient listening function
, enables the user to hear, via telephone, to what is happening in the
environment, by addressing up to 8 listening points through the vocal keypads.
Vocal help for remote management
, used by the system to guide the user with vocal messages.
Door opener
, the electric lock can be controlled via the customized output, limiting access to specific areas only to
authorised personnel. Date, time and user who have commanded the opening are recorded in the control panel.
Telephonic activation of an output without a connection charge
. By taking advantage of the GSM telephone
number recognition by the control panel, it is possible to generate a command on the specific output and close
communications after the first 3-4 rings without charging for the call.
Advanced automation
. Through the timing programmer built into the control panel, it is possible to arrange a series
of automatic and repetitive commands weekly.
Moreover, there are two auxiliary functions that are not in conformity with current laws that allow the guaranteed security
of the system to be increased easily and economically, without however replacing the dedicated systems:
Emergency response signal
, which generates service signals when a dedicated button is activated or no
movement is detected in the controlled environment.
Fire alarm
, which generates service signals from part of the control panel when fire detectors managed by the same
are installed.
IMPORTANT!
If the “emergency response call” is required, it is necessary to have a remote emergency response
system in conformity with current legislation on this topic.
To create a system that fully meets all the requirements of a fire detection system, consult Urmet
’s general
catalogue in the Fire Prevention section.