LBT20064
The electric output U2
can be configured as “Positive Reference” or “Negative Reference” via the JP2 jumper. The
factory setting of the outpu
ts is “Negative Reference”.
The electric outputs can be transformed into relay outputs
The figure illustrates how to position, for example, the JP2 jumper.
Figure 32 - Configuration of the electric output hardware
Functions associated do the DIP-switches
To activate the reset functions associated with the DIP-switches, it is necessary to follow the indications found in
paragraphs 7.9.4
Resetting hardware installer code and Tech. Manager Code
and 7.9.5
DIP-SWITCH
POSITION
FUNCTION
1
OFF
Normal operation
ON *
Reset hardware factory settings
2
OFF
Normal operation
ON *
Reset Technician code
*
=
if positioned on ON before “POWER ON”
Table 6 - Functions associated with the DIP-switches of the mother board
Factory setting
POSITIVE
reference
NEGATIVE
reference