CALL MODULES
PROGRAMMING
9
2.05 ADDITIONAL RING DURING PICK-UP TIME
P 2. 0 5
In this step we can turn on an additional call signal (after main call
signal) played in doorphone until we pick it up.
The options are:
0
Disabled,
1
Enabled.
Press and hold
#
button to save value.
Default setting
-
1
2.06 GLOBAL RING TONE TYPE
P 2. 0 6
In this step we can choose 1 of 3 available ring tones. It changes
ring tones in all doorphones unless it will be changed individually
(user change his ring tone manually).
The options are:
1
Ring tone no. 1,
2
Ring tone no. 2,
3
Ring tone no. 3.
Press and hold
#
button to save value.
Default setting
-
1
2.07 GLOBAL RING TONE VOLUME
P 2. 0 7
In this step we can choose 1 of 4 available volume levels. It
changes ring tones volume level in all doorphones unless it will be
changed individually (user change his ring tone volume level
manually).
The options are:
1
Volume level - quiet,
4
Volume level – loudest.
Press and hold
#
button to save value.
Default setting
-
4
2.08 LENGHT OF CALL SIGNAL
P 2. 0 8
After pressing
#
button actual length of call signal will be displayed.
Press shortly
#
button to leave this parameter unchanged or enter
new value within 1 – 10 seconds range.
Press and hold
#
button to save value.
Default setting
-
5
2.09 PICK-UP TIME
P 2. 0 9
In this step we can set time, after which call will be cancelled if
handset won’t be picked up.
After pressing
#
button actual pickup time expressed in seconds will
be displayed.
Press shortly
#
button to leave this parameter unchanged or enter
new value within 1 – 30 seconds range.
Press and hold
#
button to save value.
Default setting
-
20
2.10 MAXIMAL CONVERSATION LENGTH TIME
P 2. 1 0
In this step we can set maximal time, after which conversation will
end.
After pressing
#
button actual time expressed in seconds will be
displayed.
Press shortly
#
button to leave this parameter unchanged or enter
new value within 1 – 120 seconds range.
Press and hold
#
button to save value.
Default setting
-
120
2.11 MAXIMAL TIME BETWEEN KEY PRESSED
P 2. 1 1
In this step we can set maximal time between key pressed.
After pressing
#
button actual time expressed in seconds will be
displayed.
Press shortly
#
button to leave this parameter unchanged or enter
new value within 1 – 10 seconds range.
Press and hold
#
button to save value.
Default setting
-
3
2.12
TURNING OFF OPENING BUTTON DURING LOUD
CONVERSATIONS **
P 2. 1 2
Reason to use this function is to rule out accidental openings during
a conversation.
When you press # the display shows the current value of the
parameter. The parameter value is expressed in %.
We can choose:
0
Function inactive - the system works "normally",
1 – 100
The higher the value the more difficult to obtain an
accidental opening of the electrical lock with loud
conversation. Please note that the increase of parameter
hinder the normal opening.
To save new parameter please press
#
button.
Default settings
-
0