background image

EXTRAS 

DOORPHONE SYSTEM IN STANDARD CONFIGURATION  

- CALL MODULE REF 1062/105..105D 

 
 

20

 

       

-L

+L

LU

0L

AC1

AC2

VDD

GND

OC1
PS
OC2
EI1
EI2
EI3

EI4

C+

C-

ELECTRICAL DOOR LOCK

FOR EG. POWER SUPPLY

1
2

-L

+L

0L

+L

3
4

5
6
7
8

~230V

  GT1975

B

łę

dy kasuj przyciskiem......

4

Aby otworzy

ć

 drzwi

wci

ś

nij.................................

oraz
wprowad

ź

 kod otwarcia

i zatwierd

ź

 przyciskiem........

#

#

*

*

7

Wybierz numer lokalu
i poczekaj na po

łą

czenie

lub zatwierd

ź

 przyciskiem...

#

1

5

6

0

8

#

9

2

3

BASIC

 

Содержание 1062/100

Страница 1: ...DIGITAL DOOR PHONE SYSTEM Call module with keyboard Ref 1062 100 100D 1062 105 105D Version April 8th 2011 Software version 1 12 ...

Страница 2: ...H x W x D 152 x 110 x 23 35 mm ref 1062 100D Dimension H x W x D 175 x 135 x 23 6 mm with frame 525 RP2 Weight 0 8 kg DIGITAL CALL MODULE WITH KEYBOARD REF 1062 105 105D GENERAL INFORMATION Digital call module with keyboard Ref 1062 105 105D combined with power supply GT1975 and doorphones is a full door phone installation It is based on MIWUS call module Mod 525 2 modules It is offered with two t...

Страница 3: ...rrent double call signal this option can be turned on from 1 to 30 seconds Conversation is possible when user pick up the handset During conversation user can open the door press open the door button on doorphone Pressing this button will generate confirmation signal The electrical lock will be open as long as we programmed it range 1 to 30 s It will be indicated by dashes on display Maximum time ...

Страница 4: ...g after call 5 Change of individual code After entering specific function we can Press button to exit Press button to confirm Enter new value and press button to confirm 1 RING TONE P u 1 In this step we can choose 1 of 3 available ring tones To save setting press button Default setting 0 global ring tone step 2 06 2 RING TONE VOLUME LEVEL P u 2 In this step we can choose 1 of 4 predefined levels ...

Страница 5: ...5 in programming menu ENTERING PROGRAMMING MODE In order to enter programming mode Double press 0 button Enter 8 digits access password Press button to confirm Default password 21082004 After entering correct password the following will appear P 0 In BASIC system there is two level programming menu First level is defined with 0 to 6 digit and means group of parameters Second level is defined by 2 ...

Страница 6: ...ngs 1 3 Electrical lock time of working 1 4 OC1 and OC2 time of working P 4 X X Passwords Opening codes Call codes and Access control 0 1 Change Programming of logical call codes 0 2 Change Programming of individual opening codes 0 3 Change Programming of general opening codes 0 4 Adding Dallas key to the user 0 5 Identifying Deleting of Dallas key 0 6 Identifying Deleting of Dallas key according ...

Страница 7: ... range This parameter is expressed in ms Press and hold button to save value Default setting 100 ms 1 06 MINIMAL LENGTH OF OPENING IMPULSE ms P 1 0 6 In this step you can change minimal length of opening impulse opening impulse is an impulse which causes opening the door electrical lock release Press shortly button to leave this parameter unchanged or enter new value within 1 20 range This paramet...

Страница 8: ...E IN IDLE STATE V P 1 1 4 In this step you can change value of current in LU line while this line is in idle state Press shortly button to leave this parameter unchanged or enter new value within 3 0 8 0 range This parameter is expressed in V Press and hold button to save value Default setting 6 0 V 2 GLOBAL SETTINGS 2 01 CALL CODE CONFIRMATION P 2 0 1 In this step you can set parameter responsibl...

Страница 9: ...f handset won t be picked up After pressing button actual pickup time expressed in seconds will be displayed Press shortly button to leave this parameter unchanged or enter new value within 1 30 seconds range Press and hold button to save value Default setting 20 2 10 MAXIMAL CONVERSATION LENGTH TIME P 2 1 0 In this step we can set maximal time after which conversation will end After pressing butt...

Страница 10: ... The options are 0 Normal 1 Reverse only DC In this mode to the outputs C C shouldn t be directly connected electromagnetic lock It can damage the call module Press and hold button to save value Default setting 0 3 05 ELECTRICAL LOCK RELEASE P 3 0 5 In this step we can set electrical lock release in dependence on event The electrical lock will be released after event occurs or after specified even...

Страница 11: ...80R 2 OC1 activated automatically during conversation 4 OC1 activated after entering individual opening code preceded with double press of button 8 OC1 activated after entering individual opening code preceded with single press of button Dallas key or DOOR button on handset 16 Activation with EI4 input after connecting EI4 with GND 32 Activation with EI3 input after connecting EI3 with GND 64 Acti...

Страница 12: ...ed call code then this code would be displayed After that we can Leave current code or enter new one within 1 9999 range Press and hold button to save One logical code can be assigned only to one physical code If you try to assign existing logical code to another physical code it will be removed from the old location Default settings for riser 1 codes 1 to 100 In case of change of logical code qua...

Страница 13: ...ed confirmation signal In case of failure Er02 error message will be displayed and error signal will be generated as well An error may occur if given Dallas key has already been assigned to another code 4 05 IDENTIFYING DELETING OF DALLAS KEY WITH DALLAS KEY In this step we can identify or delete the Dallas key with Dallas key use After entering this step the following will appear P 4 0 5 After pr...

Страница 14: ... restore factory settings of call codes 5 07 RESTORE INDIVIDUAL OPENING CODES P 5 0 7 To activate this function press button This function will restore factory settings of individual opening codes individual codes changed manually by user will be restored as well 5 08 RESTORE GENERAL OPENING CODES P 5 0 8 To activate this function press button This function will restore factory settings of general...

Страница 15: ...0 then active is original table of codes and in this step we can only view the number of the table If parameter in step 6 07 is set to 1 then we can view or change the existing table To change the table enter new number of table and then press and hold button NOTE After changing number of table it is required to enter step 5 07 and activate new table 6 SERVICE FUNCTIONS 6 01 EDIT AND CHANGING ENTE...

Страница 16: ...ware version is 1039 the following will appear 1 0 3 9 Press button to exit option 6 10 INDIVIDUAL SETTINGS RESET P 6 1 0 Use this function to restore global and factory setting to the parameters which can be modified by user This function will affect global so individual settings of all users will be reset This function will restore Ring tone setting Ring tone volume level setting Confirmation si...

Страница 17: ...in programming menu E r 0 6 This logical code exist in system E r 0 7 Incorrect logical code format E r 0 8 Incorrect physical code format E r 0 9 This Dallas key is already associated in system E r 1 0 Memory is full CALL MODULE 1062 100 100D AND 1062 105 105D ADJUSTMENT Board of the call module is pre adjusted during production process Potentiometers P1 P2 P3 allows for module adjustment but do ...

Страница 18: ...locks 6 Insert terminal blocks into sockets in way that labels on block will match labels on board cover 7 Close the front panel 8 Fasten the front panel with two screws FLUSH MOUNTED VERSION For flush mounted version it is recommend to use the frame ref 525 RP2 sold separately in order to hide any inaccuracies of the hole execution To flush mount 1 Take the front panel off 2 Disconnect the termin...

Страница 19: ... OC1 PS OC2 EI1 EI2 EI3 EI4 C C ELECTRICAL DOOR LOCK FOR EG POWER SUPPLY 1 2 L L 0L L 3 4 5 6 7 8 230V GT1975 Błędy kasuj przyciskiem 4 Aby otworzyć drzwi wciśnij oraz wprowadź kod otwarcia i zatwierdź przyciskiem 7 Wybierz numer lokalu i poczekaj na połączenie lub zatwierdź przyciskiem 1 5 6 0 8 9 2 3 BASIC ...

Страница 20: ... OC1 PS OC2 EI1 EI2 EI3 EI4 C C ELECTRICAL DOOR LOCK FOR EG POWER SUPPLY 1 2 L L 0L L 3 4 5 6 7 8 230V GT1975 Błędy kasuj przyciskiem 4 Aby otworzyć drzwi wciśnij oraz wprowadź kod otwarcia i zatwierdź przyciskiem 7 Wybierz numer lokalu i poczekaj na połączenie lub zatwierdź przyciskiem 1 5 6 0 8 9 2 3 BASIC ...

Страница 21: ...PLY 1 2 L L 0L L 3 4 5 6 7 8 230V GT1975 GND RING BUTTON MIN 45 OHM ELECTRICAL DOOR LOCK DOOR LOCK RELASE DIRECT CALL BUTTON Błędy kasuj przyciskiem 4 Aby otworzyć drzwi wciśnij oraz wprowadź kod otwarcia i zatwierdź przyciskiem 7 Wybierz numer lokalu i poczekaj na połączenie lub zatwierdź przyciskiem 1 5 6 0 8 9 2 3 BASIC ...