CALL MODULES
PROGRAMMING
8
1.10 LEVEL OF CURRENT FOR SHORT-CIRCUIT DETECTION
[mA]
P 1. 1 0
In this step you can change level of the current for short-circuit
(value of the current at which system detects short-circuit in LU
line). Press shortly
#
button to leave this parameter unchanged or
enter new value within 100 – 300 range.
This parameter is
expressed in [mA].
Press and hold
#
button to save value.
Default setting
-
250 mA
1.11 DIFFERENCE OF LINE CURRENT REQUIRED TO OPEN
[mA]
P 1. 1 1
In this step you can change difference of line current required to
open the door. Press shortly
#
button to leave this parameter
unchanged or enter new value within 1 – 100 range.
This parameter
is expressed in [mA].
Press and hold
#
button to save value.
Default setting
-
25 mA
1.12 LEVEL OF CURRENT FOR FUNCTIONAL BUTTON [mA]
P 1. 1 2
In this step you can change value of current in LU line that system
detects doorphone functional button pressed. Press shortly
#
button to leave this parameter unchanged or enter new value within
1 – 100 range.
This parameter is expressed in [mA].
Press and hold
#
button to save value.
Default setting
-
20 mA
1.13 LEVEL OF CURRENT FOR OFF DETECTION [mA]
P 1. 1 3
In this step you can change value of current to OFF detection.
Press shortly
#
button to leave this parameter unchanged or enter
new value within 1 – 100 range.
This parameter is expressed in
[mA].
Press and hold
#
button to save value.
Default setting
-
30 mA
1.14 DOORPHONE LINE VOLTAGE IN IDLE STATE [V]
P 1. 1 4
In this step you can change value of current in LU line while this line
is in idle state. Press shortly
#
button to leave this parameter
unchanged or enter new value within 3.0 – 8.0 range.
This
parameter is expressed in [V].
Press and hold
#
button to save value.
Default setting
-
6.0 V
2. GLOBAL SETTINGS
2.01 CALL CODE CONFIRMATION
P 2. 0 1
In this step you can set parameter responsible for 1 of 2 ways to
call:
0
Just enter code (without pressing
#
button),
1
Enter the code and then press
#
button.
Press and hold
#
button to save value.
Default setting
-
0
2.02 DOOR OPEN CONFIRMATION
P 2. 0 2
In this step we can choose if we can have confirmation signal in
doorphones after opening the door:
0
Disabled,
1
After entering individual opening code preceded by single
pressing of
#
button or after opening the door with Dallas key,
2
After entering individual opening code preceded by double
pressing of
#
button,
3
Both 1 and 2 situations.
Press and hold
#
button to save value.
Default setting
-
3
2.03 KEYBOARD VOLUME LEVEL
P 2. 0 3
In this step we can adjust volume level of sounds generated by
keyboard. Options are:
0
MUTE,
7
Max volume level.
Press and hold
#
button to save value.
Default setting
-
1
2.04 KEYBOARD BACKLIGHT BRIGHTNESS ADJUSTMENT
P 2. 0 4
In this step we can adjust the brightness of keyboard backlight.
After entering this step actual value of backlight brightness will be
shown on display:
5 0
Press shortly
#
button to leave this parameter unchanged or enter
new value within 0 – 100 range.
This parameter is expressed in [%].
0
No
backlight,
100
Max backlight brightness.
Press and hold
#
button to save value.
Default setting
-
50