LX31/41 Electric Work Platform
3-7
M
AINTENANCE
Section
3.7
3.7 B
ATTERY
M
AINTENANCE
Hazard of explosive gas mixture. Keep sparks,
flame, and smoking material away from battery.
Always wear safety glasses when working with
batteries.
Battery fluid is highly corrosive. Thoroughly
rinse away any spilled fluid with clean water.
Battery Inspection and Cleaning
Check battery fluid level daily, especially if work plat-
form is being used in a warm, dry climate. If required,
add distilled water ONLY. Use of tap water with high
mineral content will shorten battery life.
The batteries and cables should be inspected regu-
larly for signs of cracks in the cases, electrolyte leak-
age and corrosion of the terminals. Inspect cables for
worn spots or breaks in the insulation and for broken
cable terminals.
Clean the batteries when it shows signs of corrosion
at the terminals or when electrolyte has overflowed
during charging. Use a baking soda solution to clean
the battery, taking care not to get the solution inside
the cells. Rinse thoroughly with clean water. Clean
batteries and cables contact surfaces to a bright
metal finish whenever a cable is removed.
3.8 L
UBRICATION
Refer to Table 3-1 for the lubrication intervals and
Figure 3-7 for location of items that require lubrica-
tion service. Refer to the appropriate sections for
lubrication information on the Steering Linkage,
Torque hubs, and Hydraulic Oil and Filter.
Grease Fittings
Wipe each grease fitting before and after greasing.
Using multipurpose grease in a grease gun, pump
the grease into the fitting until grease just begins to
appear at the edges of the pivot, wipe off any excess
grease.
Steering Linkage
Apply one or two drops of penetrating oil to each
pivot and King Pin bearing
Torque Hubs
NOTE: Change oil in torque hubs after the first 50
hours of operation. Change every 2000
hours thereafter.
1. Remove Torque Hub from drive assembly (refer
to “3.15 Torque Hub” on page 3-17).
2. Remove drain plug from underside of Torque
Hub.
3. Drain oil from unit.
4. Replace drain plug.
5. Remove fill plug from top side of torque hub.
6. Remove fill level plug from side of hub.
7. Fill unit with SAE 90 gear oil until oil comes out fill
level plug opening (1/2 full).
8. Replace fill level plug. Replace fill plug.
Figure 3-7: Lubrication Chart
W A R N I N G
!
!
Содержание LX31
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ...ii LX31 41 Electric Work Platform FORWARD NOTES ...
Страница 24: ...2 12 LX13 41 Electric Work Platform MACHINE PREPARATION OPERATION Section 2 10 NOTES ...
Страница 37: ...LX31 41 Electric Work Platform 3 13 MAINTENANCE Section 3 11 Figure 3 15 Hydraulic Manifold Exploded View ...
Страница 49: ...LX31 41 Electric Work Platform 3 25 MAINTENANCE Section 3 19 NOTES ...
Страница 66: ...4 16 LX31 41 Electric Work Platform TROUBLESHOOTING Section 4 9 ...
Страница 74: ...5 8 LX31 41 Electric Work Platform SCHEMATICS Section 5 4 ...
Страница 115: ...LX31 41 Electric Work Platform 6 41 ILLUSTRATED PARTS BREAKDOWN Section 6 1 ...
Страница 117: ...LX31 41 Electric Work Platform 6 43 ILLUSTRATED PARTS BREAKDOWN Section 6 1 ...
Страница 118: ...6 44 LX31 41 Electric Work Platform ILLUSTRATED PARTS BREAKDOWN Section 6 1 NOTES ...
Страница 119: ......