LX31/41 Electric Work Platform 4-15
T
RO U B L E S H O O T I N G
Section
4.9
Figure 4-3: Upright Tachometer Board
Battery Positive supply
(48 Volts)
A
No connection
B
No connection
C
Output over speed relay con-
nects to pin 7 of MOS90
D
Battery positive to over speed
relay (48 Volts)
E
D
Fuse
F1
Tach
Circuit
Over
speed
relay
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Battery Negative Supply
Tach speed signal to pin 12 of MOS90
Input from tach generator
Tach direction signal to pin 2 of MOS90
Input from tach generator
Tach generator
No connection
48 Volts = no over speed condition
0 Volts = over speed condition
2
Tach speed signal from tach board
7.5 Volts to 15 volts = 0-100% speed in FWD.
7.5 Volts to 0 volts = 0-100% speed in REV.
4
Tach direction signal
18 Volts = REV.
0 Volts = FWD.
3
5
Output of tach generator
0 to +50 Volts = 0-100% speed in FWD.
0 to -50 Volts = 0-100% speed in REV.
Содержание LX31
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ...ii LX31 41 Electric Work Platform FORWARD NOTES ...
Страница 24: ...2 12 LX13 41 Electric Work Platform MACHINE PREPARATION OPERATION Section 2 10 NOTES ...
Страница 37: ...LX31 41 Electric Work Platform 3 13 MAINTENANCE Section 3 11 Figure 3 15 Hydraulic Manifold Exploded View ...
Страница 49: ...LX31 41 Electric Work Platform 3 25 MAINTENANCE Section 3 19 NOTES ...
Страница 66: ...4 16 LX31 41 Electric Work Platform TROUBLESHOOTING Section 4 9 ...
Страница 74: ...5 8 LX31 41 Electric Work Platform SCHEMATICS Section 5 4 ...
Страница 115: ...LX31 41 Electric Work Platform 6 41 ILLUSTRATED PARTS BREAKDOWN Section 6 1 ...
Страница 117: ...LX31 41 Electric Work Platform 6 43 ILLUSTRATED PARTS BREAKDOWN Section 6 1 ...
Страница 118: ...6 44 LX31 41 Electric Work Platform ILLUSTRATED PARTS BREAKDOWN Section 6 1 NOTES ...
Страница 119: ......