LX31/41 Electric Work Platform 4-11
T
RO U B L E S H O O T I N G
Section
4.8
8 Flashes
- Ther mal cutback
- Heatsink temperature less
than 80ºC (176ºF) (Current
limit will be zero at 90ºC
(194ºF)
- Allow unit to cool down, to
clear flashing
Check current limit setting
Re-set
Check mounting and heatsink of controller
Rectify
Check application is correct
Use larger controller
Replace MOS90 Controller
10 Flashes
- Tachometer fault
- Drive inhibited
- Recycle key to clear fault
Check tachometer wires for opens or shorts
Rectify
Check output voltage from tachometer using
voltmeter
Replace
Check output voltage from tachometer board,
using voltmeter
Replace
Replace MOS90 Controller
Содержание LX31
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ...ii LX31 41 Electric Work Platform FORWARD NOTES ...
Страница 24: ...2 12 LX13 41 Electric Work Platform MACHINE PREPARATION OPERATION Section 2 10 NOTES ...
Страница 37: ...LX31 41 Electric Work Platform 3 13 MAINTENANCE Section 3 11 Figure 3 15 Hydraulic Manifold Exploded View ...
Страница 49: ...LX31 41 Electric Work Platform 3 25 MAINTENANCE Section 3 19 NOTES ...
Страница 66: ...4 16 LX31 41 Electric Work Platform TROUBLESHOOTING Section 4 9 ...
Страница 74: ...5 8 LX31 41 Electric Work Platform SCHEMATICS Section 5 4 ...
Страница 115: ...LX31 41 Electric Work Platform 6 41 ILLUSTRATED PARTS BREAKDOWN Section 6 1 ...
Страница 117: ...LX31 41 Electric Work Platform 6 43 ILLUSTRATED PARTS BREAKDOWN Section 6 1 ...
Страница 118: ...6 44 LX31 41 Electric Work Platform ILLUSTRATED PARTS BREAKDOWN Section 6 1 NOTES ...
Страница 119: ......