1 Principle of operation

The programmable temperature controller T-87IF allows 

 programming switching events (up to 9) and temperatures 

 according to personal needs. After installation the device auto-

matically shows the time of day and the room temperature. In 

AUTO mode, the heater will be automatically activated accor-

ding to  programmed time and temperature. Program 1 is the 

default pre-set program (see 8.).
Room temperature will be controlled, the floor temperature will 

be limited (measured by the remote sensor). The heater will be 

switched on when the temperature drops below the current 

set-point. 
In case of function „Min Floor Temp“ (H3) it will be heated if the 

floor temp drops below the set min-value. This is even when the 

room temp. is too high.
In case of function „Max Floor Temp“ (H3) heating will be stop-

ped if the floor temp exceeds the set max-value. This is even 

when the room temp. is too low.

2 Installation

Caution!

This device must be installed by a qualified electrician, 

according to the wiring diagram on the device and in com-

pliance with all applicable safety regulations. 
Appropriate installation measures must be taken to achieve 

the requirements of protection class II.
This device, is used to control the temperature only in 

dry rooms, under normal environmental conditions. This 

electronic device conforms to EN 60730, It is an “indepen-

dently mounted control” and works according to operating 

principle 1C.

3 Use

The electronic Room Temperature Controller T-87IF can be used 

to control the room temperature in conjunction with:
•  Electrical floor heating systems where the floor temperature 

has to be limited to a certain value

•  Hot-water floor heating systems in conjunction with 

thermal actuators

In order to measure the floor temperature the remote 

sensor has to be used

4 Features

• One line text display for simplified operation
• Back light 
• Real time clock (setting of year, month, day, time)
• Automatic Summer- Winter time change over
• Max 9 events per day (each day independently)
• Pre-set and adjustable programs
• Optimum-Start
• Arm chair programming (with display unit removed)
• OFF-Function, Key V to be pressed for 10 sec
• Holiday-Mode (date from - until can be set)
•  Timer (Party) specific temperature for configurable duration
•  Energy consumption display (heating on time * cost) for last 2 

days, -week, -month, -year

• Energy cost per hour configurable
• Frost protection
• Range limits for adjusting max and min temperature
• Access protection
• Operating language can be selected
• Control mode PWM or ON/OFF
•  Minimum output on/off time and hysteresis configurable for 

ON/OFF control

Remote Sensor

20

Ø7,8

8. Pre-set programs

There are 3 pre-set time/temperature programs in the  controller. 

Pre-set program 1 (as shown below) is the default. Therefore, if 

pre-set program 1 is the best program to suit the application, 

there will be no need to change the  time/temperature settings 

on the device.
To select another program see 9. G1.

Program 1 

Monday to Friday

Events

1

2

3

4

5

6

Time

6:00

8:30

12:00 14:00 17:00

22:00

Temperature °C

21,0

18,0

21,0

18,0

21,0

15,0

Saturday and Sunday

Events

1

2

3

4

5

6

Time

7:00

10:00 12:00 14:00 17:00 23:00/22:00*

Temperature °C

21,0

18,0

21,0

21,0

21,0

15,0

6:00 h

8:00 h

10:00 h

12:00 h

14:00 h

16:00 h

18:00 h

20:00 h

22:00 h

Mon – Fri
Sat – Sun

*23:00/22:00 = 23:00 for Saturday

Program 2

Monday to Friday

Events

1

2

3

4

5

6

Time

6:00

8:30

12:00 14:00 17:00

22:00

Temperature °C

21,0

18,0

21,0

18,0

21,0

15,0

Saturday and Sunday

Events

1

2

Time

7:00

23:00/22:00*

Temperature °C

21,0

15,0

6:00 h

8:00 h

10:00 h

12:00 h

14:00 h

16:00 h

18:00 h

20:00 h

22:00 h

Mon – Fri
Sat – Sun

*23:00/22:00 = 23:00 for Saturday

Program 3

Monday to Friday

Events

1

2

5

6

Time

6:00

8:30

17:00

22:00

Temperature °C

21,0

18,0

21,0

15,0

Saturday and Sunday

Events

1

2

3

4

Time

7:00

10:00

12:00 23:00/22:00*

Temperature °C

21,0

18,0

21,0

15,0

6:00 h

8:00 h

10:00 h

12:00 h

14:00 h

16:00 h

18:00 h

20:00 h

22:00 h

Mon – Fri
Sat – Sun

*23:00/22:00 = 23:00 for Saturday

Notes for Programming

•  Activated settings terminate automatically 3 Min after the last 

key press, without saving. They return to the mode which was 

active before entering the settings, e.g. AUTO, MAN, etc.

• Entering a Code: change value with 

+ – 

key then press OK

•  When going through User- or Installer settings the item num-

ber used in the manual will be displayed, e.g. G1 for „Program 

select one“ or H2 for „Control Mode“.

• There may be gaps in the sequence of menu numbers.

Troubleshooting

1. It is getting warm too late: 

 

a.  Are clock and program events set correctly?

 

b.  Is the Optimum Start feature switched on? see H7 

Did the controller have enough time (several days) to 

adapt to the room’s characteristics? 

 

c.  Is an automatic change between Summer- and Winter 

time activated, see G5

2.  The controller does not accept any changes 

Is access protection switched on? see G6

3.  The range of temperature setting is limited. 

Are temperature limits set? See G7

4.  Temperature display doesn‘t change. 

Is display of set-temperature activated? See G10

5.  The room heats up too slow 

The floor temperature may be limited from the 

controller‘s max-limiter. See H3

6.  The room becomes too warm 

The floor temperature may be limited from the 

controller‘s Min-limiter. See H3

• Min- and max limits for floor temperature adjustable 
• Valve protection 
• Adaptation to valves normally open or normally closed
•  Adjustable heating interrupt according standard EN 50559 

(not for valves normally open)

Electric connection

Caution:

 disconnect electric circuit from supply

Connecting according to Wiring Diagram
For flexible or solid wires 1 - 2,5 mm2

Connecting the remote sensor

The T-87IF needs a remote temperature sensor. This sensor 

should be mounted in such a way that the temperature which 

has to be controlled, can be measured correctly. Lay sensor insi-

de a protective tube (simplifies replacement). The sensor lead 

can be extended up to 50 m by using a cable and  connections 

suitable for 230 V. Avoid laying sensor cable alongside power 

cables, for example inside a conduit.

Caution! 

The sensor is at mains voltage.

6 Technical Data

Order Type

T-87IF

Supply voltage

230 V AC 50 HZ (207 … 253 V) 

Temperature setting range

5 °C … 30 °C; in 0,5 °C steps

Temperature resolution 

0,1°C steps

Output

Relay NO contact

Switching current

10mA … 12,5(4)A AC; 230 V~

Output signal

 PWM (Pulse Width modulation) 

or ON/OFF

PWM cycle time

adjustable

Hysteresis 

adjustable (ON/OFF only)

Minimum programmable time

10 Min

Power consumption 

~ 1,2 W

Accuracy of clock

< 4 Min / year

Power reserve

~ 10 Years

Remote sensor

 length 4 m, can be extended 

up to 50 m

Ambient temperature 

  Operating 

  Storage

without condensation 

0 °C … 40 °C 

–20 °C … 70 °C

Rated impulse voltage 

4 kV

Ball pressure test

75 ± 2 °C

Voltage and Current for the 

purposes of Interference mea-

surements

230 V, 0,1 A

Degree of protection

IP 30

Protection class of housing

II (see Caution)

Pollution degree

2

Software class

A

Weight (with remote sensor)

~ 280 g

Energy class

  (acc. EU 811/2013, 812/2013, 

813/2013, 814/2013)

IV = 2 %

7 Wiring Diagram / Dimensions

Sensor

L

N

N

230V~ 50Hz

L

N

Load

Actual Day

Actual

Room

Temperature

Calling for 

Heat (Blinks if 

detached from 

power module 

or there is no 

mains power)

Helping text

Mode = AUTO

Time = 14:31

The controller should be mounted at a location in the room which:
• can be easily accessed
• is free of curtains, cabinets, shelves, etc.
• allows free air circulation
• is not exposed to direct sunlight
• is not draughty (when doors or windows are opened)
• is not directly influenced by the source of heat
• is not located on an outer wall
• is approx. 1.5 m above the floor.

Fitting

in a conduit box Ø 60 mm
• remove the display unit
• remove the frame
•  Mount it following the reverse 

 procedure

Caution! 

Mounting in plastic wall boxes only

5. Mounting

To insert or remove a 

flexible wire press pin

The plastic tab must be in place to provide insulation 

between the terminals/wires and the mounting screw.

Caution! 

Maximum length 

of removed cable 

insulation 8 mm.

9 Description of Functions and Operation

Selecting languages

Only for products where no language is pre-set, user has to set up his language by doing this: 

ENGLISH

  

+ – 

to select language 

 

(This input is only requested at first start or Reset) 

 

2 x OK

 to accept -> AUTO will be displayed (to change language 

again use menu G14)

How the T-87IF Temperature Controller can be used

Change temperature until next switching event

 

see keys, + – in AUTO

Set temperature for a number of hours

 

see main menu, TIMER

Adjust the controller to personal needs

 

see main menu, USER-SETTINGS

 Controlling the temperature according to pre-set profiles

 

see main menu, AUTO

Set temperature for a specific date

 

see main menu, HOLIDAY

Adjust the controller to application needs

 

see main menu, INSTALLER-SETTINGS

Set a constant temperature (manual operation)

 

see main menu, MAN

Use a separate program for special days

 

see main menu, AT-HOME

Keys

to confirm / activate

+ –  in AUTO (-)

Set temperature temporarily until next switching event. Indicated by „-“ behind AUTO-. First key-press shows set value, following ones change it.

OK

+ – in menu

Scroll through the menu

OK

Accepts modification / selection

Info

Show related details in AUTO, MAN, TIMER, HOLIDAY, AT-HOME. To cancel press key again

Menu

Enter menus. + – Key to move

V

Go one step back

V

 for 10 sec

Switch off connected load. Display shows OFF. Details see G4

Main Menu

to confirm / activate

A

MENU

Use + – in order to navigate through the menu

B

AUTO

The temperature will be controlled automatically according to the time and temperature of the selected program, see G1. Use + – keys to change temperature 

until next switching event.

OK

C

MAN

The temperature will be controlled continuously according to the temperature set in this menu. Use + – key to change temperature.

OK

D

TIMER

The temperature will be controlled temporarily according to the hours and temperature set in this menu. On terminating TIMER mode, the previously active 

mode will be re-activated. Holiday terminates Timer.

OK

E

HOLIDAY

The temperature will be controlled between the dates and the temperature set in this menu. Holiday starts at 0h of the first day, it ends at 24h of the last day. 

In the period of time before HOL starts, AUTO will be active. While waiting for holiday start date, other mode can be selected (AUTO, MAN, TIMER, HOME). INFO 

provides details of the pending holiday. In this situation holiday period will start automatically when the DATE  FROM occurs. When holiday ends it returns to the 

mode which was in place before activating holiday. 

OK

F

AT HOME

The temperature will be controlled automatically according to the time and temperature of the program configured here (independent from AUTO). The pro-

gram is the same for all days. Monday‘s program is used as the pre-set. It needs to be terminated by user, e.g, by selecting AUTO. Usage: for holiday at home, 

illness etc.

OK

G

USER SETTINGS 

Customise the controller according to personal requirements

OK

H

INSTALLER SETTINGS 

Customise the controller according to application requirements (from installer only)

OK

G

USER SETTINGS

Customise the controller according to personal requirements

default settings

( ) = value range

1

Program select

Select one of the pre-defined programs, see 8. (If another program is chosen, settings will not be saved)

P1  (P … P3)

2

Event Setting

Modify Time and Temperature of active program, see 8. Each event can be reduced to the previous one or to 00:00h. Each event can be extended up to 23:50h, 

then 

->>> is indicating that the event is in the next day. By pressing + or  key at ->>> a time can be adjusted. Max 9 events are possible. The first digit indicates the 

actual event e.g. 3.12:00- 14:00 shows event 3. Events can be set for day-blocks as well, when selecting days  (Mon...Fri, Sat/Sun, Mon...Sun). In order to finish pro-
gramming, press 

V

 repeatedly. 

as selected at G1

3

Clock Settings

Set Date and Time

4

Off Heating Permanent

Switch off the heater, the controller remains on power. Display reading OFF. Frost protection may happen if selected. See H6. Switching ON again by activating 
e.g. AUTO or by pressing key 

V

 for 10 Sec. When re-activating via key 

V

 or this menu, AUTO will be activated.

NO

5

Summer/Winter time 

 change over

Select if automatic Summer/Winter-Time changeover

YES

6

Key Lock

Protect controller against unauthorised use. Re-activate via code = 93

NO

7

Temperature limits 

min/max

Limits the temperature which can be set by the user, If both values are the same, no adjustment is possible. This affects AUTO, MAN, HOL, TIMER, AT-HOME,  

event setting (G2). The active program / mode will not be affected automatically.

5; 30 °C

8

Cost/Hr for Energy

The assumed energy cost per hour (in cent/h) can be set. To use this feature as hour counter set the cost to 100 cent/h.

100 (1 … 999)

9

Energy consumption 

to date

Shows the approximate energy cost of the controlled area. For the last: 2 days, week (7 days), month (30 days), year (365 days). On the actual day, calculation is 

up to current time. In case of overflow 9999 will be displayed. This feature mainly can be used for electric heating.

  Calculation: On-Time of heater x cost per hour see above. Reset see H9

10

Set temperature to read

Show set temperature instead of room temperature

NO

11

Adjust Temperature

Adjust temperature to personal needs 

0.0  (-5.0 … +5.0)

13

Backlight

Continuously OFF or temporarily illuminates after key press

SHORT 

(SHORT, OFF)

14

Language

Select preferred operating language

15

Info

Displays Controller-type and  -version. 

16

Reset user settings 

only

Only USER SETTINGS will be set to factory settings. The energy counter will not be re-set; to do this see H9).

NO

Change INSTALLER SETTINGS

CAUTION! 

These settings should only be set-up by a qualified person. They can influence safety and the proper functioning of the system.

H

INSTALLER SETTINGS

Customise the controller according application needs (by installer only)

default settings

( ) = value range

0

Code

Enter Code (= 7) in order to access the menus. It is valid for 1 Hour

1

Application

This controller is suitable for the heating system mentioned on right column. 

LIMITER see 1.

2

Control Mode

PWM or ON/OFF can be selected. In case of PWM, the cycle time can be set (in Minutes). Min ON/OFF time = 10% of cycle time. 

Use short time for fast and longer time for slow reacting heating systems. 

For ON/OFF you can select:

  • Hysteresis (OFF = no temperature hysteresis, even at very low changes of temp. the relay will switch over according to the Min On/Off Time setting.) 

  • Min On/Off Time (the minimum duration for the relay to be On or Off)

PWM/10  (/10 … 30)

OFF  (OFF, 0.1 … 5.0)

10 Min 

(1 … 30) 

3

Min/max Floor 

Temperature

Limits the floor temperature. Selectable is:

  • Minimum floor temperature, the floor gets no colder as this temp. (OFF = no limit); e.g. Min-Temp. = 21°, the floor will get no colder than 21° even if the room is too warm

  • Maximum floor temperature, the floor gets no warmer as this temp. (OFF = no limit); e.g. Max-temp. = 35°, the floor will get no warmer than 35°, even if the room is too cold

If one of these limits is not needed it should be set to OFF

OFF

 

(OFF, 10 … Tmax)

35 °C 

 

(OFF, Tmin … 40)

5

Valve protection

The output will be activated for the specified time each day at 10:00 h in the morning

3 min  (OFF, 1 … 10)

6

Frost protection

Set frost protection temperature. Only if controller is switched OFF, the temperature will be controlled to that value.

5 °C  (OFF, 5 … 30)

7

Optimum Start

The set temperature will be reached at the time specified in the program. During pre-heating time, AUTO_ will be displayed

YES

8

Valves NO

If valves normally open have to be used

NO

9

Energy Counter Reset 

The energy counter will be set to 0

NO

10

Display of  

floor temperature

The temperature measured from remote sensor will be displayed (for service purpose)

Temperature

11

Reset all

All INSTALLER and USER settings will be set to its Factory setting

NO

12

EN 50559 Interrupt

Interrupts heating after continous heating of 1hr for this adjusted time

5 Min  (0 … 20 Min)

10. Error Indication

In case of errors, „Err“ is blinking. The following errors can be displayed:

CONFIGURATION  

Display- and powermodule do not fit 

  

g

 use only suitable parts 

  

g

 switch off and on power supplyge 

EXT SENSOR  

1. Error of remote sensor 

 

g

 replace sensor

 

2. Over- or under run of valid display ran

COMMUNICATION 

Communication between display- and power unit fails 

  

g

 unplug and re-plug display unit 

  

g

 switch off and on power supply

On all these errors, heating will be activated with 30 % of time

11. Resistance values for remote sensor

Temperature

Resistance

Temperature

Resistance

10 °C

66,8 kΩ

30 °C 

26,3 kΩ

20 °C 

41,3 kΩ 

40 °C 

17,0 kΩ

25 °C 

33 kΩ 

50 °C 

11,3 kΩ

t

*

  This product should not be disposed of with 

household waste. Please recycle the products 

where facilities for electronic waste exist. Check 

with your local authorities for recycling advice.

Uponor Corporation

Äyritie 20
01510 Vantaa  
Finland

T +358 (0)20 129 211
F +358 (0)20 129 2841
www.uponor.com

GB

Содержание T-87IF

Страница 1: ...umbers Troubleshooting 1 It is getting warm too late a Are clock and program events set correctly b Is the Optimum Start feature switched on see H7 Did the controller have enough time several days to...

Страница 2: ...ee H6 Switching ON again by activating e g AUTO or by pressing key V for 10 Sec When re activating via key V or this menu AUTO will be activated NO 5 Summer Winter time change over Select if automatic...

Страница 3: ...h 12 00 h 14 00 h 16 00 h 18 00 h 20 00 h 22 00 h Po P So Ne 23 00 22 00 23 00 pro sobotu Program 3 pond l a p tek Ud losti 1 2 3 4 as 06 00 08 30 17 00 22 00 Teplota C 21 0 18 0 21 0 15 0 sobota a n...

Страница 4: ...oty stejn nen mo n dn se zen M to vliv na AUTO MAN DOVOLEN ASOVA DOMA programov n Aktivn program re im nebude automaticky ovlivn n 5 30 C 8 Hodinov cena za energii Mohou b t nastaveny p edpokl dan n k...

Страница 5: ...einstellbar nicht f r Ventile stromlos offen 8 Voreingestellte Programme Der Regler verf gt ber 3 voreingestellte Zeit und Temperaturprogramme Als Standardeinstellung ist Programm 1 eingestellt siehe...

Страница 6: ...n durch aktivieren einer Betriebsart z B AUTO MAN usw oder durch Taste V f r 10 Sek Bei Wiedereinschalten per Taste V oder ber dieses Men wird AUTO aktiviert NO 5 Sommer Winter Umschaltung Auswahl ob...

Страница 7: ...ingstider indstillet korrekt b Er funktionen Optimeret start aktiveret Se H7 Havde kontrolenheden nok tid flere dage til at tilpasse sig til rummets karakteristika c Er automatisk skift mellem sommer...

Страница 8: ...viser Slukket Frostbeskyttelse hvis aktiveret Se H6 Tilslutning igen ved aktivering af f eks AUTO eller ved at trykke p tasten i 10 sekunder Ved genaktivering via tasten eller denne menu aktiveres AU...

Страница 9: ...ora 06 00 08 30 17 00 22 00 Temperatura C 21 0 18 0 21 0 15 0 S bado y Domingo Periodos 1 2 3 4 Hora 07 00 10 00 12 00 23 00 22 00 Temperatura C 21 0 18 0 21 0 15 0 6 00 h 8 00 h 10 00 h 12 00 h 14 00...

Страница 10: ...invierno a verano se realice autom ticamente YES 6 Protecci n de acceso Protege el cronotermostato de manipulaciones no deseadas Para quitar la protecci n hay que introducir el c digo 93 NO 7 L mites...

Страница 11: ...Start toiminto kytketty p lle ks H7 Onko termostaatilla ollut riitt v sti aikaa useita p ivi sopeutua huoneen olosuhteisiin c Onko automaattinen vaihto kes ja talviajan v lill aktivoitu ks G5 2 Termos...

Страница 12: ...irta N yt ss lukee POIS J tymisenesto voi k ynnisty jos valittuna Ks H6 Kytke takaisin P LLE aktivoimalla esimerkiksi AUTO tai painamalla n pp int 10 sekunnin ajan Jos laite kytket n p lle painamalla...

Страница 13: ...0 22 00 Temp rature C 21 0 18 0 21 0 15 0 Samedi et dimanche Commutation 1 2 3 4 Heure 07 00 10 00 12 00 23 00 22 00 Temp rature C 21 0 18 0 21 0 15 0 6 00 h 8 00 h 10 00 h 12 00 h 14 00 h 16 00 h 18...

Страница 14: ...DE LA TEMPERATURE Limite le r glage de la temp rature plus de modification possible lorsque les deux valeurs sont identiques Ce qui a une influence sur AUTO MANUEL VACANCES MINUTERIE JOUR DEROGE PARAM...

Страница 15: ...ny nap a k zponti egys gnek hogy alkalmazkodjon a helyis g karakterisztik j hoz c Be van kapcsolva az automatikus v lt s a ny ri s a t li id sz m t s k z tt l sd G5 2 A k zponti egys g nem fogadja el...

Страница 16: ...meg jra a gombot ahogy a G1 n l kiv lasztotta 3 Ora beall Id s d tum be ll t sa 4 Futes ki tartosan Kikapcsolja a f t st a k zponti egys g bekapcsolva marad A kijelz KI Kiv laszt s ut n alkalmazhat a...

Страница 17: ...23 00 22 00 Temperatura in C 21 0 18 0 21 0 15 0 6 00 h 8 00 h 10 00 h 12 00 h 14 00 h 16 00 h 18 00 h 20 00 h 22 00 h Lun Ven Sab Dom 23 00 22 00 23 00 per sabato Avvertenze per la programmazione Le...

Страница 18: ...atura inferiori superiori Limita la temperatura regolabile se entrambi i valori sono uguali non pi possibile alcuna modifica Ci influenza programmazione delle modalit AUTO MAN VACANZE TIMER CASA slezi...

Страница 19: ...de ingestelde tijden en temperaturen b Is de optimale start ingesteld zie H7 heeft de rege laar voldoende dagen de tijd gekregen om zich vol doende in te leren c Is de zomer wintertijd ingeschakeld z...

Страница 20: ...r naar AUTO toe te gaan of door de knop V voor 10 seconden in te drukken Wanneer men teruggaat door V stand AUTO wordt geselcteerd NO 5 Zomer Winter tijd functie Hier kan men kiezen voor het automatis...

Страница 21: ...s det elementnummeret som brukes i veiledningen f eks G1 for Velg program eller H2 for Kontrollmodus Menynumrene vises ikke n dvendigvis i rekkef lge Feils king 1 Det blir varmt for sent a Er klokken...

Страница 22: ...er valgt Se H6 Sl p varmen igjen ved for eksempel aktivere AUTO modus eller ved trykke p knappen i 10 sekunder N r du aktiverer p nytt ved hjelp av knappen eller denne menyen aktiveres AUTO modus NEI...

Страница 23: ...Sob Niedz 23 00 22 00 23 00 w sobot Program 3 od poniedzia ku do pi tku Przedzia czasowy 1 2 3 4 Czas 06 00 08 30 17 00 22 00 Temperatura C 21 0 18 0 21 0 15 0 sobota i niedziela Przedzia czasowy 1 2...

Страница 24: ...omoc kodu 93 NO 7 Limit temperatury min max Ogranicza zakres temperatury jaka mo e zosta ustawiona przez u ytkownika Je eli obie granice s identyczne ustawienie nie jest mo liwe Ma wp yw na tryby AUTO...

Страница 25: ...08 30 17 00 22 00 C 21 0 18 0 21 0 15 0 1 2 3 4 7 00 10 00 12 00 23 00 22 00 C 21 0 18 0 21 0 15 0 6 00 h 8 00 h 10 00 h 12 00 h 14 00 h 16 00 h 18 00 h 20 00 h 22 00 h 23 00 22 00 23 00 3 AUTO MAN G...

Страница 26: ...K E HOLIDAY 0 24 HOL AUTO MAN TIMER AT HOME INFO HOL HOL HOL OK F AT HOME OK G USER SETTINGS OK H INSTALLER SETTINGS OK G USER SETTINGS 1 8 P1 P1 P3 2 8 00 00 23 50 9 3 12 00 14 00 3 V G1 3 4 OFF H6 A...

Страница 27: ...t a Har klockan och programh ndelserna st llts in korrekt b r funktionen OPTIMAL START aktiverad Se H7 Har rumstermostaten haft tillr ckligt med tid flera dagar f r att anpassa sig efter rumsegenskape...

Страница 28: ...m och tid 4 Varme av permanent St ng av v rmen rumstermostaten f rblir p slagen Displayen visar AV Frysskyddet kan aktiveras om det valts Se H6 Sl p v rmen igen genom att t ex aktivera AUTO eller tryc...

Отзывы: