Operating manual
RS100-4-S
BA-AB-4485-RS100-Englisch.doc
Erstelldatum 30.05.2011 14:57:00
41
Before cleaning and changing the exit screen, mount the discharge rails at the machine!
11. Repair
and
maintenance
11.1 Safety
guidelines
•
Before beginning installation and maintenance work always turn off the main switch and secure it
against switching on with a padlock!
•
Installation and maintenance work should be undertaken in strict adherence to the order stated!
•
Only original spare parts made by the manufacturer may be used (see appendix)! Otherwise the
guarantee expires!
•
Dispose of old grease in line with environmental disposal guidelines!
•
Installation and maintenance work may only be carried out by authorised expert staff in line with
the regulations concerning installation and maintenance work and accident prevention
regulations!
•
Maintenance of electrical equipment may be executed by qualified and authorised electro
personnel only!
11.2 Cleaning and changing the exit screen
•
In case of damage or signs of wear, the exit screen must be replaced!
•
If there are material blockages, the screen must be cleaned
Procedure
1. Bolt 2 mounting plates
to the
free bearing plate
.
2. Bolt 2 discharge rails
to the
understructure
of the machine.
3. Bolt 2 supports
to the discharge
rails
and the mounting plates
.
4. Bolt the beam
to the discharge
rails
.
Содержание RS100-4-S