Table C
MODELS
GAS
column A
Ø INIJECTOR
[1/100 mm]
column B
BUSHING B DIS-
TANCE
column C
XBC615EG
G20, G25, G25.1
345
H = 39mm
G30, G31
225
XBC815EG
G20, G25, G25.1
375
H = 39mm
G30, G31
235
XVC315EG
G20, G25, G25.1
275
H = 39mm
G30, G31
180
XVC515EG
G20, G25, G25.1
330
H = 39mm
G30, G31
215
XVC715EG
G20, G25, G25.1
360
H = 39mm
G30, G31
230
XVC1215EG
G20, G25, G25.1
345
H = 39mm
G30, G31
225
XVC2015EG
G20, G25, G25.1
375
H = 39mm
G30, G31
235
XVC915EG
XVC1015EG
XBC915EG
XBC1015EG
G20, G25, G25.1
340
H = 39mm
G30, G31
225
XVC4015EG
G30, G31
225
H = 39mm
Gas nozzles G30 and G31 are installed on all models
Table D - Gas valve outflow pressure
GAS
MAX pressure[mbar]
MIN pressure[mbar]
G20
14,2 ± 2%
7
G 25 - G25.1
21,2 ± 2%
10
G30 - G31
26,2 ± 2%
13
SETTINGS LABEL
LI2293A0 - Stampato: 01-2012
ww
w.un
ox.
com
XBC
For technician: cut and paste the correct current setting label
Per l’installatore: tagliare ed attaccare la corretta etichetta di settaggio
2E G20 20
mbar
2E+ G20/G25
20/25
mbar
2H G20 20mbar
2H
G20
25 mbar
2L G25 25
mbar
2LL G25 20
mbar
2S G25.1
25
mbar
3+
G30 /G31
28-30/37 mbar
3B/P
G30 /G31
28-30 mbar
3B/P
G30 /G31
37 mbar
3B/P
G30 /G31
50 mbar
GAS PARAMETER
ADJUSTMENTS AT
At installation and after
every adaptation to gas
type, remove the indelible
sticker shown in the figure
from the Starter Kit and
cut out the settings label
that has the new gas pa-
rameters. The sticker must
be applied onto the data
plate.
BakerTop
™
ChefTop
™
English
29
Содержание ChefTop XVC 2005
Страница 14: ...Getting started FREE STANDING TROLLEY OVENS 1 2 2 1 English 14...
Страница 20: ...Anchoring on UNOX substructures UNOX high open stand 1 2 x4 3 4 English 20...
Страница 25: ...2 4 5 8 10 9 11 6 7 3 OK BakerTop ChefTop English 25...
Страница 43: ...OK OK OK 2 cm 180 cm OK OK 50 cm Examples of correct and incorrect installation BakerTop ChefTop English 43...