For proper electrical connections, the appliance must:
- Be wired into an equipotential system according to what is stated in the regulations in force. This connection must
be performed between different appliances with the terminal marked with the equipotential symbol
. The
ZLUHPXVWKDYHDPD[LPXPFURVVVHFWLRQRIPPDFFRUGLQJWR,(&(1VWDQGDUGDQG
be yellow-green.
- Must be grounded
WRWKHHDUWKLQJJUHHQ\HOORZZLUH
- Must be connected to a thermal differential switch as in compliance with the regulations in force.
- Must be connected to an omnipolar circuit breaker.
Checks
- The copper jumper and the electrical cable must be secured together beneath the screw in its tightening direction; and the
electrical connections must be well secured before connecting the appliance to the electricity mains.
- check for any electrical dispersion between the phases and the ground, and for electrical continuity between the
external casing and the main ground line.
- Check that the power supply voltage does not deviate from the nominal voltage value specified on the appliance
rating plate when the appliance is operating. If this is not the case, wire the phases as specified on the "technical
specifications" sheet attached.
Adapting to different voltage
For electrical and voltage requirements that differ from standard values, it is necessary to replace the power supply
cable and connect the new cable to the terminal board following the diagrams on the
´7HFKQLFDOVSHFLILFDWLRQVµVKHHW
3RZHUVXSSO\&RQQHFWLRQ'LDJUDP
attached to the appliance.
Replacing the power supply cable
A
B
The cable must be replaced by UNOX or
by its technical assistance service, and in all
cases by a person with similar qualification
in order to avoid possible risks.
Follow the procedures below to replace the power
supply cable:
RSHQWKHWHUPLQDOERDUGFRYHUE\XQVFUHZLQJVFUHZ´$µ
- remove the cable by disconnecting it from the termi-
QDOERDUGDQGFDEOHFODPS´%µ
-
consult the "Technical Specifications" sheet
3RZHU
supply-Connection Diagram
:
the sheet indicates all
possible wiring diagrams and the specifications that
the new cable must have in reference to the wiring
selected
&DEOH7\SH
;
- secure the new cable using the cable clamp;
- Close the terminal board cover by securing the fixing
screws.
BakerTop
™
ChefTop
™
English
27
Содержание ChefTop XVC 2005
Страница 14: ...Getting started FREE STANDING TROLLEY OVENS 1 2 2 1 English 14...
Страница 20: ...Anchoring on UNOX substructures UNOX high open stand 1 2 x4 3 4 English 20...
Страница 25: ...2 4 5 8 10 9 11 6 7 3 OK BakerTop ChefTop English 25...
Страница 43: ...OK OK OK 2 cm 180 cm OK OK 50 cm Examples of correct and incorrect installation BakerTop ChefTop English 43...
Страница 79: ......