ChefTop™
3. ELECTRICAL CONNECTION
3.1 WARNING
The connection to the electrical power supply system
must be carried out according to the current local regula-
tions.
Before connecting the appliance, make sure that the volt-
age and the frequency correspond to those stated on the
data plate of the appliance.
The appliance must be placed in such a way that the con-
necting plug to the network can be easily reached.
Place an omni-polar switch between the appliance and
the network in such a way that it will be easily accessi-
ble after the installation. The contacts of this switch must
have a minimum opening distance of 3 mm and the switch
must have an appropriate input (for example: thermal-
magnetic switch).
The use of a safety switch for fault current is suggested.
When the appliance is working, the power supply voltage
must not diverge from the value of the nominal voltage,
indicated on the data plate, by more than ± 10%.
3.2 CONNECTION TO THE ELECTRICAL SUPPLY
MAINS
It is sufficient to plug in the equipment to the appropriate
outlet (the outlet must be suitable to the issued plug).
The replacement of the cable must be done by authorised
personnel.
The appliance must be connected to the ground line of
the network.
3.3 EQUIPOTENTIAL SYSTEM
The appliance must be installed to an equipotential system
whose efficiency must be properly checked according to
the current laws. This connection must be done between
different appliances through the terminal marked with the
symbol:
The equipotential conductor must have a minimum sec-
tion of 10 mm
2
.
4. WATER CONNECTION
4.1 WARNING
It is necessary to place a mechanical filter and a shut-off
valve between the water system and the appliance.
As required by current laws, the appliance is equipped
with 2 metres of pipe, the respective pipe fitting (3/4”)
with non-return valve and mechanical filter.
Before connecting the water pipe to the appliance please
let some water flow to clear the pipe of any obstruc-
tions.
The water used in the appliance must have a pressure
value between 1 and 3 bar and a maximum temperature
of 30°C.
5. OVEN CONNECTION
The prover XL404 is connected to the oven via the sup-
plied cable RJ45 .
To connect the cable of the prover to the oven proceed
as follows:
remove the safety cap by unscrewing the proper
screw
Insert the connector of the cable in one of the three
female connectors you find on the power card (any of
the three connections can be used)
Re-assemble the safety cap by fixing the screw
Now the prover is recognised by the oven control.
•
•
•
ENGLISH
8
ENGLISH
7
ENGLISH
BakerTop™