Connection to the electricity mains must be carried out in compliance with current regulations.
The appliance must be positioned so that the power plug is accessible (for appliances fitted with Schuko plugs).
Fit an omnipolar disconnection switch between the appliance and the electricity mains, making sure it remains
accessible after the installation process; it should have a minimum contact opening of 3 mm and a suitable capacity
(e.g. magneto thermal switch), with an insulation class of 4000 V.
We recommend the use of a safety switch for fault currents. During appliance operation, the power supply
voltage should not deviate from the nominal voltage value specified on the appliance rating plate, ± 10%.
Caution!
Electrical connections must be performed by technicians registered with the relevant authorities as required
by law for the country in which the appliance is installed. These technicians must, evertheless, be aware of
and apply the regulations relating to the safety of repaired products and safety in the workplace. In light of the
above information, UNOX accepts no responsibility for any situation resulting from work carried out in an
unprofessional manner, or from the incorrect interpretation or application of regulations.
Attention!
Before connecting the prover to the electricity mains, compare the power supply data with the appliance
requirements specified on its rating plate. If the voltages and power supply phases are different, adjust
and correct the phase wiring, in accordance with the data provided on the attached leaflets. Make sure no
electricity is dispersed between the phases and earth.
Make sure there is electrical continuity between the outer casing and the electricity mains earth wire.
We recommend the use of a digital multimeter when performing these procedures.
Incorrect connection may damage the appliance.
Caution!
Make sure all electrical connections are secure before connecting the appliance to the electricity mains.
Simply insert the plug into the relevant socket (the socket should be suitable for use with the plug supplied).
19
Electrical connections