Preliminary and positioning procedures
Installation site
Before positioning the appliance, check the measurements and the exact position of the electrical, plumbing
and smoke exhaust connections, in accordance with the figures provided in the enclosed “Technical Data”
booklet.
Caution!
Do not install the appliance near flammable materials. If the appliance is positioned near walls, partitions,
kitchen cabinets, decorative trim, etc., these items must be made from non-flammable material. If this is not
the case, they must be coated with a non-flammable heat insulating material, and all fire prevention regulations
must be strictly observed.
Removing the protective film
Carefully remove the protective film from the outer surfaces of the appliance,
so that no glue residue is left behind. Any remaining residue can be removed
using a suitable solvent product.
Positioning
Warning
Position the appliance so that the back panel is easily accessible when performing electrical connection and
carrying out maintenance work. The appliance is not suitable for recessed installation, or for use as part of
a series of appliances. A minimum gap of 50 mm must be left around the entire perimeter of the appliance.
If any fryers or other potential sources of hot liquid spills are used in the kitchen, they should be placed at least
45 cm away from the sides and 70 cm away from the back of the prover.
450 mm
700 mm
50 mm
50 mm