86
3)
Select whether to enable alarm input. If
Alarm Input
is set to
On
, the terminal will receive door magnet
alarms. If it is set to
Off
, the terminal will not receive door magnet alarms.
(3)
Set actions to be associated with door magnet alarms.
Door magnet alarms can be associated with the terminal snapshot action. Select whether to enable the
function based on actual scenes.
(4)
Set whether to enable the arming schedule.
Select the
Enable Plan
check box and set the start time and end time of alarms (click
Edit
). The time ranges
cannot be overlapped. The device outputs alarm signals only within the preset valid time ranges.
The options of day include Monday to Sunday and the time of each day is defined using four time ranges.
After setting the plan time for one day, you can click Copy and then click Paste on another day to copy the
plan time to other days.
Drawing Arming Time by Using the Mouse
Editing Tables to Set Arming Time
(5)
Click
Save
.
7.3.6
Storage
1. Storage
(1)
Click
Setup
>
Storage
>
Storage
.
NOTE!
Keep default values on the
Storage
interface. Configuration is forbidden.
Formatting is forbidden.
2. FTP
The configuration is not supported.
7.3.7
Security
1. User
For user configuration, see
User
.
2. Network Security
After security information transmission is set, you can
establish an
information security
channel to ensure data
transmission security.
(1)
HTTPS
(1)
Click
Setup
>
Security
>
Network Security
>
HTTPS
.