In response to the current epidemic, companies, parks, and communities take temperatures and check mask
wearing for people passing through the entrances and exits. The work is performed by people manually, which is
exhausting and increases the risk of cross-infection. The face recognition access control terminal is capable of
checking whether people are wearing masks and taking their temperatures (an intelligent digital detection module
is required, and either the forehead temperature or wrist temperature can be taken). For people with abnormal
temperature (exceeding the preset maximum temperature threshold) or without masks, the face recognition
access control terminal displays an alarm on the GUI, plays a warning sound. and determines whether to open the
door based on actual application scenes, thereby achieving epidemic prevention and control. For detailed
configuration, see
Intelligent — Advanced Setting
NOTE!
When the temperature measurement function is enabled to take the forehead temperature, a person needs to
get close to occupy the human shape on the screen and aim the forehead center at the red circle, as shown in
. When the wrist temperature needs to be taken, a person needs to aim the wrist at the temperature-
measuring point of the digital detection module.
Ensure that the forehead or wrist is at a proper distance from the intelligent digital detection module. For OEP-
BTM32-NB, the recommended distance is 0.5–0.7m. For OEP-BTS1-NB, the recommended distance is 1–2.5cm.
When the forehead temperature needs to be taken, the forehead cannot be covered by fringes, hats, sunglasses,
or other objects. When the wrist temperature needs to be taken, the wrist cannot be covered by sleeves,
watches, bracelets, or other objects. Such objects, if any, need to be removed from the forehead or wrist 0.5 to
1 minute before the temperature can be taken.
The temperature measurement function requires an intelligent digital detection module, which can be connected
to the visual intercom face recognition terminal through RS485. For the configuration, see
Do not use the temperature measurement function together with the safety helmet/safety module function.
1. Mask detection and temperature measurement
Enable both the mask detection and temperature measurement functions on the visual intercom face recognition
terminal. When a person (whose information is stored in the library) passes through the terminal, the GUI displays
the detection result.
NOTE!
The following figures show interfaces of forehead temperature measurement. The interfaces of wrist temperature
measurement are basically the same as those of forehead temperature measurement except that no human shape
and red circle are displayed on the GUI. For the wrist temperature measurement interface, see
Figure 5-8
.