![UNIVIEW OET-213H Скачать руководство пользователя страница 88](http://html.mh-extra.com/html/uniview/oet-213h/oet-213h_user-manual_1059615088.webp)
83
7. Sensing
The configuration is not supported.
7.3.5
Events
You can set alarm arming to implement alarm reporting. By configuring triggered actions of other devices, an
alarm can trigger one or more types of actions, so that the users handle the alarm and the corresponding actions
in time.
Alarm arming includes fire alarms, anti-disassembly alarms, and door magnet alarms.
1. Fire alarms
When the face recognition terminal connects to a fire alarm device, the terminal will generate a fire alarm record
when a fire alarm occurs.
(1)
Choose
Setup
>
Events
>
Events
and then click
Fire Alarm
.
Figure7-54
Fire Alarm Configuration Interface
(2)
Set fire alarm information.
1)
Select alarm and set the alarm name.
2)
Select
N.O.
or
N.C.
according to the type of the third-party alarm input device. For example, if the third-
party alarm input device is normally open, you need to select
N.O.
here, so that the camera can receive
alarm information from the third-party alarm input device.
3)
Select whether to enable Alarm Input. If
Alarm Input
is set to
On
, the terminal will receive alarms from
the fire alarm device. If it is set to
Off
, the terminal will not receive alarms from the fire alarm device.
(3)
Set actions to be associated with fire alarms.
Fire alarms can be associated with terminal snapshot and door opening actions. Select whether to enable
the two functions based on actual scenes.
(4)
Set whether to enable the arming schedule.
Select the
Enable Plan
check box and set the start time and end time of alarms (click
Edit
). The time ranges
cannot be overlapped. The device outputs alarm signals only within the preset valid time ranges.