1 Basic - Information
9
Technical Data
For battery voltages up to 48V=
Power supply connection
24V= bis 48 V=
Please indicate battery voltage on order!
Auxiliary voltage connection
24V= ±10% / 2A
Residual ripple <10%,
regenerating fuse
Specifikation
BAMOBIL-D3.2-62-
Dim.
80
120
250
350
450
Supply voltage
V=
24 to 48
Max. output voltage
V~eff
3x14 to 3x33
Continuous current
A
eff
40
60
125
175
225
Peak current max.
A
I o
80
120
250
350
450
Max. Power loss
W
200
300
600
900
1200
Pulse frequency
kHz
8
Over voltage
switching threshold
V=
programmable up to max. 68V
Input fuse
A
80
160
250
250
500A
Weight
kg
5.5
5.8
6.8
6.8
6.8
Dimensions h
x
w
x
d
mm
244x194x90
Unit size
2
2
2
2
2
For battery voltages up to 120V=
Power supply connection
24V= bis 120V=
Batteriespannung bei Bestellung angeben!
Auxiliary voltage connection
24V= ±10% / 2A
Residual ripple <10%,
regenerating fuse
Specification
BAMOBIL-D3.2-160-
Dim.
50
100
150
Supply voltage
V=
24 to 120
Max. output voltage
V~eff
3x14 to 3x78
Continuous current
A
eff
25
50
75
Max. peak current
A
I o
50
100
150
Max. Power loss
W
200
300
600
Pulse frequency
kHz
8
Over voltage
Switching threshold
V=
programmable to max. 160V
Input fuse
A
80
160
250
Weight
kg
5.5
5.8
6.8
Dimensions h
x
w
x
d
mm
244x194x90
Unit size
2
2
2
Содержание Bamobil D3.2