3 Electrical Installation
Power connections
Attention:
The order of the connections to the connector or terminal numbers is obligatory. All
further advice is non-obligatory.
The input and output conductors may be altered or supplemented in accordance
with the electrical standards and guidelines.
Adhere to:
- connection and operating instructions
- local regulations
- EU guideline 89/392/EWG
- VDE and TÜV regulations and Trade body guidelines
Electrical installation should only be carried out when all
voltages have been removed!
Ensure that the device is safely disconnected from the power
supply
- place the short-circuit bracket
- affix warning signs
The installation should only be carried out by suitably trained
personnel for electrical engineering.
- Compare the connection data with those indicated on the type plate.
- Ensure that the correct fuses have been provided for the power supply
and the auxiliary voltage.
- Power supply conductors and control lines must be routed separately from
each other.
Connection shields and grounding must be carried out in compliance
with the EMC guidelines. Use the correct line cross-sections.
Warning:
Bad or insufficiently rated cable connections between the battery and the device
may cause damage to the device! (Brake energy)
Warning:
Power supply cables between the BAMOBIL and the battery must be as short as
possible.
Long cables cause dynamic voltage drops due to the line impedance and as a
consequence the service life of the installed ELKOs would be
reduced.
Warning:
Concerning the power supply connection and the auxiliary
voltage connection of the battery please check:
negative power supply voltage = negative auxiliary voltage
The internal connection is destroyed in case of a reverse polarity
of the auxiliary voltage.