24
BAMOBIL D3.2
Motor power connection
Only electronically commutating synchronous motors (brushless dc motors, EC
motors) with resolver or incremental encoder must be used. These motors must be
approved of by UNITEK prior to any use.
See appendix A (Motor specific connection and parameter standards and
guidelines).
Sequence of connection
Motor cable
3-core, single-shielded for
200V=,
shield capacity = 150pF/m,
min. Cross-section - see below
table
Min. cable cross-section
Motor choke
Only necessary for a shield capacity of >5nF. Approx. 25m motor cable
Magnetic rings
against HF failures of the sensor systems. Slide the rings onto the motor lines.
Connection of the shield
Surface-to-surface connection to the switch cabinet input.
Surface-to-surface connection as short as possible to the motor side.
Cable
M1
M2
M3
Motor phases
U
V
W
Connecting bolt
XB:2
XB:3
XB:4
Only one correct connecting sequence is possible !
BAMOBIL-D3-x
-50
-80
-100
-120
-150
-250
-350
-450
Cross-section mm²
4
6
6
10
16
25
70
95
AWG
10
10
10
6
4
2
000
0000
Motor connectors
or terminal cabinet
Motor choke
Incremental encoder
EC
Содержание Bamobil D3.2
Страница 3: ...1 Basic Information 3...
Страница 16: ...16 BAMOBIL D3 2...
Страница 18: ...18 BAMOBIL D3 2 Core REFERENCE...
Страница 19: ...19 3 Electrical Installation Mains module Output stage 6x op coup driver...