11
2 Mechanical Installation
I
mportant instruction
Check the device for mechanical damage. Only perfect devices can be mounted.
Disconnect the power supply prior to any assembly.
Disconnect the positive battery pole.
The device must only mounted by suitably trained personnel.
The mounting position of the devices with ground plate and those
with additional cooling unit (air by means of fan, liquid) is arbitrary.
Devices with an additional cooling unit without a fan must be
mounted vertically.
Please note that there will be a performance reduction when they are
mounted horizontally.
Ensure that the ventilation is sufficient and that there is enough space for the discharged
ventilation air (min. 100mm). If the heat is not dissipated sufficiently the device switches off
via its temperature watchdog.
Any bore hole dimensions for the fixation of the device must be taken from the dimension
diagrams or from the drilling plan, not from the device.
The filter and the choke have to be mounted near to the device.
The line shields and the mounting plate must have surface-to-surface contact.
The power supply lines (battery line and motor line) must be routed separately from each
other. Observe the min. line cross-section.
Unshielded cable heads must be kept short.
8mm cable lugs
Use vibration-proof screw connections.
Note:
Concerning the power supply connection and the auxiliary voltage
connection of the battery please check:
negative power supply voltage = negative auxiliary voltage
The internal connection is destroyed in case of a reverse polarity of
the auxiliary voltage.
Содержание Bamobil D3.2
Страница 3: ...1 Basic Information 3...
Страница 16: ...16 BAMOBIL D3 2...
Страница 18: ...18 BAMOBIL D3 2 Core REFERENCE...
Страница 19: ...19 3 Electrical Installation Mains module Output stage 6x op coup driver...