BAMO A1, A2 60-500
15
3 Electrical installation
Ready for operation signal BTB
Relay
signal contact
X2:12 - X2:13
contact values
max. 48V; 0,5A
The ready for operation signal (BTB) shows the CNC/PLC
that the drive is ready for operation.
Switch BTB- signals of several axes in one row.
delay after switching on mains
>>>
max. 1sec.
Function
Indication
BTB-Relay
Ready for operation
LED bright green
Contact closed
Not ready for operation
LED glims green
Contact open
Error
LED bright red
Contact open
BTB turns off with
Error is
Overtemperature
not stored
Overvoltage
stored
Short, Line-to-earth-fault
stored
Voltage error
not stored
To reset store switch off/on enable
Caution:
Use BTB-contact always with CNC/PLC - control
or with emergency-stop circuit !
Self-starting possible!
Fault memory is not effective with all faults !
“Blocked” Indication
Current demand
Outpu X2:14
Normal
> +10V
Overload
< +2V
Analogue measuring putputs
Function
Motor current display
Speed display
Connection
X2:9 , X1:7
X2:8 , X1:7
Value peek current
+5.0V
Value steady current
+2.5V
In
d
ic
a
tio
n
s