26
BAMO A1, A2 60-500A
G
e
ttt
in
g
sta
rte
d
command value 0V
enable drive
LED BTB glim green
overtemperature
LED "fault" red bright
short in motor connection
motor speeds up
tacho connection
mixed up or
interruped
switch off mains
clear failure
increase comm.value
up to10%
Motor stands still
check comm.value
check motor connection
motor runs jerky
reduce amplification X
P
adjust speed with
poti n
max
to 10%
increase comm.value
to 100%
adjust speed to 0
with trimmer Offset
Speed cannot be adjusted
resistor R23 wrong
mains voltage too low
current limit too low
adjust current limits
peek current with I
max
and
steady current I
D
to
motor data
Getting Started
finished
optimize drive
fill in protocol
Default setup
switch on mains
LED BTB
bright green
Motor stands still
or runs smooth slow
Motor runs smooth
with ca. 10%
Motor runs smooth
with ca. 100%