![Unitek BAMO A1 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/unitek/bamo-a1/bamo-a1_manual_4028908013.webp)
BAMO A1, A2 60-500
13
3 Electrical installation
Command value-speed
voltage source for command values ±10V, 10mA
+10V
X1:3
-10V
X1:5
GND
X1:7
Command value input
- command value input maximum ±10V=
- differential input
- input resistance 50 k
W
- relay contacts: gold- or reed contacts
Caution
command value lines paired twisted and shielded. Screen connection one-sided.
Connection:
Command value voltage with internal supply
command value
X1:4 (signal)
X1:7 (GND)
bridge
X1:6 — X1:7
External command value voltage SPS/CNC
command value
X1:4 (signal)
X1:6 (GND)
External command value current SPS/CNC
Resistance for command value current 0 ... ± 20mA >>> R-comm. = 500
W
command value current
X1:4 (signal)
X1:6 (GND)
Int.supply
CNC/PLC
Comm.value current
With
A1
(1Q) only positiove command value
leave out d2 and connection X1:5 is not coated
Caution:
do not use a command value current between 4 and 20mA
C
o
m
m
a
n
d
va
lu
e