BAMO A1, A2 60-500
25
5 Adjustment
Default setup
Check connections before getting started
Connection
Voltage
Clamp
Battery connection
Max. 36V or max.160V
X3:2
X3:10
Auxiliary voltage
24V= ± 20%
X3:13
X3:14
Motor connection
max. 30V or max. 150V
X3:4
X3:8
NOTICE Technical data !!!
Basic connections - power supply
Battery
2x power connection,
NOTICE POLARITY!
Motor
2x Motor line
Basic connections - control connections
Auxiliary voltage
24V= ± 20%
X3:13 , X3:14
Ready for operation (BTB)
Contact between
X2:11 , X2:12
Enable
Contact between
X1:1 und X1:2
Comm.value from PLC
Differential input ±10V
X1:4 , X1:6
Comm.value - internal supply with trimmer
Bridge X1:6-X1:7
A1 (1Q)
Positiv e 10V
X1:3 (GND X1:7)
A2 (4Q)
Positive 10V
X1:3
Negative 10V
X1:5
Comm.value
± 10V
X1:4
Act.value tachometer
± 160V
X2:8 (GND X1:7)
Armature voltage regulation no actual value connection. Jumper J1 plugged!
Default setup for first getting started
Function
Potentiometer
Adjustment
Peek current
I
max
20%
Steady current
I
D
100%
Amplification
X
P
10%
Speed
n
max
0%
D
e
fa
u
lt
se
tu
p