PHASEMASTER™ 6 DIRECT ENERGY WELDING CONTROL
990-083
3-1
CHAPTER 3
OPERATING INSTRUCTIONS
Section I: Operation
Power Up
Switch the rear panel Circuit Breaker to "ON". To prevent firing until ready to weld, select [NO WELD].
Set the Transformer Tap Switch to its lowest tap position, Tap 1 on UNIPULSE Transformers.
Select Run or Program State
The PM6 has two States, the RUN State and the PROGRAM State. Press [PROGRAM] to enter the
PROGRAM State which is signified by the flashing of one of the numeric fields (SCHEDULE NUMBER,
POLARITY, SQUEEZE, WELD, HOLD, or %CURRENT). Press [RUN] to enter the RUN State. Welding
is done in the RUN State.
Select Schedule
Press [RUN] if any of the numeric fields are flashing. Press [
?
/
?
] to select any Schedule Number from 0 to 7.
Each schedule will be displayed together with its Polarity, Squeeze Cycles, Weld Cycles, Hold Cycles and
%Current.
NOTE:
Squeeze Cycles and Hold Cycles are used only for Air Operated Weld Heads. These fields will
remain blank if a Manual Weld Head is connected.
Change Schedule Parameters
Press [
?
/
?
] to select a Schedule. Schedule 0 can be changed at any time that the PM6 is placed in the
Program State. Schedules 1 through 7 can only be changed if the Schedule Protection Feature is switched to
OFF. See Change Schedule Protection.