APPENDIX A: TECHNICAL SPECIFICATIONS
PHASEMASTER™ 6 DIRECT ENERGY WELDING CONTROL
990-083
A-13
Section II. UNIPULSE Transformer Specifications and
Features
UNIPULSE Transformer designs guarantee repeatable output energy even during half-cycle operation.
They are convection cooled. However, their performance and duty cycle can be increased by optional fan
cooling. The four models shown in figure A-2 include a primary tap switch. The red pilot lamp on the front
of the UNIPULSE Transformer lights when voltage is applied to the transformer primary. Below are
UNIPULSE Transformer specifications and characteristics.
Transformer Specifications
Model
Primary
Voltage
volts
Input KVA
Duty Cycle
Taps
Output Voltage
volts (rms)
Short
CKT
Current
amps
3%
8%
50%
Prim.
Sec.
X2 / 115RF
115
3.1
1.9
0.75
4
0
3.8, 2.4, 1.5, 1.0
2400
X2 / 230RF
230
3.1
1.9
0.75
4
0
3.8, 2.4, 1.5, 1.0
2400
X2 / 115
115
2.5
2.5
1.0
4
0
3.2, 2.7, 2.4, 2.0
2300
X2 / 230
230
2.5
2.5
1.0
4
0
3.2, 2.7, 2.4, 2.0
2300
X5 / 115HV
115
9.8
4.5
1.8
4
2
14 to 1.8 in 24 steps
1800
X5 / 115HV
230
9.8
4.5
1.8
4
2
14 to 3.5 in 12 steps
1800
X8 / 230
230
13.0
8.0
3.2
8
0
5.8, 5.3, 4.8, 4.4, 4.0,
3.6, 3.3, 3.0
9200
X16 / 230
230
26.0
16.0
6.4
3
2
5.6, 4.9, 4.3 (HI-COM)
3.8, 3.3, 2.9 (LO-COM)
1.9, 1.6, 1.4 (HI-LO)
16000
X16 / 480
480
26.0
16.0
6.4
3
2
5.6, 4.9, 4.3 (HI-COM)
3.8, 3.3, 2.9 (LO-COM)
1.9, 1.6, 1.4 (HI-LO)
16000