- 107 -
MS926 User’s Manual
FE is the “Compare characters” command
31 is the hex value for 1
F7 is the “Move the cursor to the beginning” command
F2 is the “Send a number of characters” command
06 is the number of characters to send
0D is the hex value for a CR
The data is output as:
123456
<CR>
■
Move the cursor to the end
EA
Move the cursor to the last character in the input message. Syntax = EA.
4.8.4.3 Search Commands
■
Search forward for a character
F8
Search the input message forward for “xx” character from the current
cursor position, leaving the cursor pointing to the “xx” character. Syntax =
F8xx where xx stands for the search character’s hex value for its ASCII
code. Refer to
the ASCII Conversion Chart (Code Page 1252)
, for
decimal, hex and character codes.
F8 Example: Send bar code data that starts after a particular character
Search for the letter “D” in bar codes and send all the data that follows,
including the “D.” Using the bar code above:
Command string:
F844F10D
F8 is the “Search forward for a character” command
44 is the hex value for “D”
F1 is the “Send all characters” command
0D is the hex value for a CR
The data is output as:
DEFGHIJ
<CR>