Bar Code Symbologies
Modify the output characteristics of 16 of the most popular bar
code symbologies in current use. Following are the bar code
symbologies and their modifiable parameters.
Code 39
•
Enabled
toggles the ability for the scanner to read Code 39 on or
off.
Default is “Yes”.
•
Code ID (Standard)
is a user-definable identification letter for
Standard Code 39, which is referred to in the “Use Code ID”
function on page 25.
Default is letter “M”.
•
Code ID (Full ASCII)
is the same as Code ID (Standard),
above, except that the symbology is Full ASCII Code 39.
Default is also letter “M”.
•
Type
toggles Code 39 between Standard and Full ASCII.
Default is “Full ASCII”.
•
Check Digit
defines whether or not a check digit (to insure
data accuracy) is calculated, and if so, whether it should be
sent or not.
Default is “Not Calculate”.
•
Send Start/Stop
toggles sending or not sending start/stop
sentinels (* in the case of Code 39).
Default is “No Send”.
•
Minimum Length
defines the minimum length the user will
accept for a valid bar code.
Default is “0”.
•
Maximum Length
defines the maximum length the user will
accept for a valid bar code.
Default is “48”.