P O R T A L T I +
Portal Installation Manual
18
Document #: PTL1001
Figure 13. Portal Interior
3.4
Connecting Power
The Portal TI+ uses an IEC-320-C13 male power inlet to supply the unit with power. This
inlet can be found on the back wall on the right-hand side of the Portal TI+ case.
1. Locate main power wires. There will be three 16 AWG (or greater) environmentally
rated black, white, and green colored wires.
2.
Route the main power wires to the Portal’s input power connector and remove excess
wire length, leaving sufficient length to reach the AC power inlet.
3. Remove the 3-pronged AC connector from the AC power inlet (supplied with the
Portal)
4. Disassemble the outer housing.